ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Internal radiation exposure dose in Iwaki City, Fukushima Prefecture after the accident at Fukushima Dai-ichi Nuclear Power Plant.

https://repo.qst.go.jp/records/47282
https://repo.qst.go.jp/records/47282
de545fdf-5e25-4070-bdea-f9c2a540833b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-09-15
タイトル
タイトル Internal radiation exposure dose in Iwaki City, Fukushima Prefecture after the accident at Fukushima Dai-ichi Nuclear Power Plant.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Orita, Makiko

× Orita, Makiko

WEKO 472908

Orita, Makiko

Search repository
Hayashida, Naomi

× Hayashida, Naomi

WEKO 472909

Hayashida, Naomi

Search repository
Nukui, Hiroshi

× Nukui, Hiroshi

WEKO 472910

Nukui, Hiroshi

Search repository
Fukuda, Naoko

× Fukuda, Naoko

WEKO 472911

Fukuda, Naoko

Search repository
Kudo, Takashi

× Kudo, Takashi

WEKO 472912

Kudo, Takashi

Search repository
matsuda, Naoki

× matsuda, Naoki

WEKO 472913

matsuda, Naoki

Search repository
Fukushima, Yoshiko

× Fukushima, Yoshiko

WEKO 472914

Fukushima, Yoshiko

Search repository
Takamura, Noboru

× Takamura, Noboru

WEKO 472915

Takamura, Noboru

Search repository
松田 尚樹

× 松田 尚樹

WEKO 472916

en 松田 尚樹

Search repository
福島 芳子

× 福島 芳子

WEKO 472917

en 福島 芳子

Search repository
抄録
内容記述タイプ Abstract
内容記述 As a result of the accident at the Fukushima Daiichi Nuclear Power Plant (FNPP) on 11 March 2011, a huge amount of radionuclides, including radiocesium, was released and spread over a wide area of eastern Japan. Although three years have passed since the accident, residents around the FNPP are anxious about internal radiation exposure due to radiocesium. In this study, we screened internal radiation exposure doses in Iwaki city of Fukushima prefecture, using a whole-body counter. The first screening was conducted from October 2012 to February 2013, and the second screening was conducted from May to November 2013. Study participants were employees of ALPINE and their families who underwent examination. A total of 2,839 participants (1,366 men and 1,473 women, 1–86 years old) underwent the first screening, and 2,092 (1,022 men and 1,070 women, 1–86 years old) underwent the second screening. The results showed that 99% of subjects registered below 300 Bq per body in the first screening, and all subjects registered below 300 Bq per body in the second screening. The committed effective dose ranged from 0.01–0.06 mSv in the first screening and 0.01–0.02 mSv in the second screening. Long-term follow-up studies are needed to avoid unnecessary chronic internal exposure and to reduce anxiety among the residents by communicating radiation health risks.
書誌情報 PLOS ONE

巻 9, 号 12, p. e11407, 発行日 2014-12
出版者
出版者 Public Library of Science
関連サイト
識別子タイプ URI
関連識別子 http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4257669/
関連名称 http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4257669/
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:41:39.704877
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3