DEVELOPMENT OF A COMPUTER CODE TO CALCULATE THE DISTRIBUTION OF RADIONUCLIDES WITHIN THE HUMAN BODY BY THE BIOKINETIC MODELS OF THE ICRP.

https://repo.qst.go.jp/records/47248
https://repo.qst.go.jp/records/47248
ee51c543-1ab1-478a-b56d-2c641d501589
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-08-11
タイトル
タイトル DEVELOPMENT OF A COMPUTER CODE TO CALCULATE THE DISTRIBUTION OF RADIONUCLIDES WITHIN THE HUMAN BODY BY THE BIOKINETIC MODELS OF THE ICRP.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsumoto, Masaki

× Matsumoto, Masaki

WEKO 472535

Matsumoto, Masaki

Search repository
Yamanaka, Tsuneyasu

× Yamanaka, Tsuneyasu

WEKO 472536

Yamanaka, Tsuneyasu

Search repository
Hayakawa, Nobuhiro

× Hayakawa, Nobuhiro

WEKO 472537

Hayakawa, Nobuhiro

Search repository
Iwai, Satoshi

× Iwai, Satoshi

WEKO 472538

Iwai, Satoshi

Search repository
Sugiura, Nobuyuki

× Sugiura, Nobuyuki

WEKO 472539

Sugiura, Nobuyuki

Search repository
松本 雅紀

× 松本 雅紀

WEKO 472540

en 松本 雅紀

Search repository
岩井 敏

× 岩井 敏

WEKO 472541

en 岩井 敏

Search repository
抄録
内容記述タイプ Abstract
内容記述 This paper describes the Basic Radionuclide vAlue for Internal Dosimetry (BRAID) code, which was developed to calculate the time-dependent activity distribution in each organ and tissue characterised by the biokinetic compartmental models provided by the International Commission on Radiological Protection (ICRP). Translocation from one compartment to the next is taken to be governed by first-order kinetics, which is formulated by the first-order differential equations. In the source program of this code, the conservation equations are solved for the mass balance that describes the transfer of a radionuclide between compartments. This code is applicable to the evaluation of the radioactivity of nuclides in an organ or tissue without modification of the source program. It is also possible to handle easily the cases of the revision of the biokinetic model or the application of a uniquely defined model by a user, because this code is designed so that all information on the biokinetic model structure is imported from an input file. The sample calculations are performed with the ICRP model, and the results are compared with the analytic solutions using simple models. It is suggested that this code provides sufficient result for the dose estimation and interpretation of monitoring data.
書誌情報 Radiation protection dosimetry

発行日 2014-07
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
PubMed番号
識別子タイプ PMID
関連識別子 25061129
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncu233
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:42:06.557879
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3