WEKO3
アイテム
Methodology Using a Portable X-Ray Fluorescence Device for On-Site and Rapid Evaluation of Heavy-Atom Contamination in Wounds: A Model Study for Application to Plutonium Contamination
https://repo.qst.go.jp/records/47190
https://repo.qst.go.jp/records/47190c5cfb6aa-77c7-4148-b434-d78049c5a366
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-07-27 | |||||
タイトル | ||||||
タイトル | Methodology Using a Portable X-Ray Fluorescence Device for On-Site and Rapid Evaluation of Heavy-Atom Contamination in Wounds: A Model Study for Application to Plutonium Contamination | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshii, Hiroshi
× Yoshii, Hiroshi× Yanagihara, Kouta× Imaseki, Hitoshi× Hamano, Tsuyoshi× Yamanishi, Hirokuni× Inagaki, Masayo× Sakai, Yasuhiro× Sugiura, Nobuyuki× Kurihara, Osamu× Sakai, Kazuo× 吉井 裕× 柳原 孝太× 今関 等× 濱野 毅× 杉浦 紳之× 栗原 治× 酒井 一夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Workers decommissioning the Fukushima-Daiichi nuclear power plant damaged from the Great East Japan Earthquake and resulting tsunami are at risk of injury with possible contamination from radioactive heavy atoms including actinides, such as plutonium. We propose a new methodology for on-site and rapid evaluation of heavy-atom contamination in wounds using a portable X-ray fluorescence (XRF) device. In the present study, stable lead was used as the model contaminant substitute for radioactive heavy atoms. First, the wound model was developed by placing a liquid blood phantom on an epoxy resin wound phantom contaminated with lead. Next, the correlation between the concentration of contaminant and the XRF peak intensity was formulated considering the thickness of blood exiting the wound. Methods to determine the minimum detection limit (MDL) of contaminants at any maximal equivalent dose to the wound by XRF measurement were also established. For example, in this system, at a maximal equivalent dose of 16.5 mSv to the wound and blood thickness of 0.5 mm, the MDL value for lead was 1.2 ppm (3.1 nmol). The radioactivity of 239Pu corresponding to 3.1 nmol is 1.7 kBq, which is lower than the radioactivity of 239Pu contaminating puncture wounds in previous severe accidents. In conclusion, the established methodology could be beneficial for future development of a method to evaluate plutonium contamination in wounds. Highlights: Methodology for evaluation of heavy-atom contamination in a wound was established. A portable X-ray fluorescence device enables on-site, rapid and direct evaluation. This method is expected to be used for evaluation of plutonium contamination in wounds. | |||||
書誌情報 |
PLOS One 巻 9, 号 7, p. e101966-e101966, 発行日 2014-07 |
|||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | doi:10.1371/journal.pone.0101966 |