  1. 原著論文

Skull counting in late stages after internal contamination by actinides

https://repo.qst.go.jp/records/47180
https://repo.qst.go.jp/records/47180
35679d67-f846-4d7d-bbdc-d0ff6e1f22bd
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-07-23
タイトル
タイトル Skull counting in late stages after internal contamination by actinides
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tani, Kotaro

× Tani, Kotaro

WEKO 471488

Tani, Kotaro

Search repository
Shutt, Arron

× Shutt, Arron

WEKO 471489

Shutt, Arron

Search repository
Kurihara, Osamu

× Kurihara, Osamu

WEKO 471490

Kurihara, Osamu

Search repository
Kosako, Toshiso

× Kosako, Toshiso

WEKO 471491

Kosako, Toshiso

Search repository
谷 幸太郎

× 谷 幸太郎

WEKO 471492

en 谷 幸太郎

Search repository
栗原 治

× 栗原 治

WEKO 471493

en 栗原 治

Search repository
抄録
内容記述タイプ Abstract
内容記述 Monitoring preparation for internal contamination with actinides (e.g., Pu, Am) is required to assess internal doses at nuclear fuel cycle-related facilities. In this paper, the authors focus on skull counting in case of single-incident inhalation of 241Am and propose an effective procedure for skull counting with an existing system, taking into account the biokinetic behavior of 241Am in the human body. The predicted response of the system to skull counting under a certain counting geometry was found to be only about ~1.0×10-5 cps Bq-1 one year after intake. However, this disadvantage could be remedied by repeated measurements of the skull during the late stage of the intake due to the predicted response reaching a plateau at about the 1000th day after exposure and exceeding that in the lung counting. Further studies are needed for the development of a new detection system with higher sensitivity to perform reliable internal dose estimations based on direct measurements.
書誌情報 Radiation Protection Dosimetry

巻 163, 号 3, p. 381-386, 発行日 2015-02
出版者
出版者 Oxford University Press.
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
PubMed番号
識別子タイプ PMID
関連識別子 24920571
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:42:58.806016
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3