  1. 原著論文

Carbon-ion scanning lung treatment planning with respiratory-gated phase-controlled rescanning: Simulation study using 4-dimensional CT data

https://repo.qst.go.jp/records/47172
https://repo.qst.go.jp/records/47172
b3696db4-949f-4f7b-adfe-597448539f21
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-07-22
タイトル
タイトル Carbon-ion scanning lung treatment planning with respiratory-gated phase-controlled rescanning: Simulation study using 4-dimensional CT data
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takahashi, Wataru

× Takahashi, Wataru

WEKO 471390

Takahashi, Wataru

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 471391

Mori, Shinichiro

Search repository
Nakajima, Mio

× Nakajima, Mio

WEKO 471392

Nakajima, Mio

Search repository
Yamamoto, Naoyoshi

× Yamamoto, Naoyoshi

WEKO 471393

Yamamoto, Naoyoshi

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 471394

Inaniwa, Taku

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 471395

Furukawa, Takuji

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 471396

Shirai, Toshiyuki

Search repository
Noda, Koji

× Noda, Koji

WEKO 471397

Noda, Koji

Search repository
Nakagawa, Keiichi

× Nakagawa, Keiichi

WEKO 471398

Nakagawa, Keiichi

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 471399

Kamada, Tadashi

Search repository
高橋 渉

× 高橋 渉

WEKO 471400

en 高橋 渉

Search repository
森 慎一郎

× 森 慎一郎

WEKO 471401

en 森 慎一郎

Search repository
中嶋 美緒

× 中嶋 美緒

WEKO 471402

en 中嶋 美緒

Search repository
山本 直敬

× 山本 直敬

WEKO 471403

en 山本 直敬

Search repository
稲庭 拓

× 稲庭 拓

WEKO 471404

en 稲庭 拓

Search repository
古川 卓司

× 古川 卓司

WEKO 471405

en 古川 卓司

Search repository
白井 敏之

× 白井 敏之

WEKO 471406

en 白井 敏之

Search repository
野田 耕司

× 野田 耕司

WEKO 471407

en 野田 耕司

Search repository
中川 恵一

× 中川 恵一

WEKO 471408

en 中川 恵一

Search repository
鎌田 正

× 鎌田 正

WEKO 471409

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background: To moving lung tumors, we applied a respiratory-gated strategy to carbon-ion pencil beam scanning with multiple phase-controlled rescanning (PCR). In this simulation study, we quantitatively evaluated dose distributions based on 4-dimensional CT (4DCT) treatment planning.
Methods: Volumetric 4DCTs were acquired for 14 patients with lung tumors. Gross tumor volume, clinical target volume (CTV) and organs at risk (OARs) were delineated. Field-specific target volumes (FTVs) were calculated, and 48Gy(RBE) in a single fraction was prescribed to the FTVs delivered from four beam angles. The dose assessment metrics were quantified by changing the number of PCR and the results for the ungated and gated scenarios were then compared.
Results: For the ungated strategy, the mean dose delivered to 95% of the volume of the CTV (CTV-D95) was in average 45.3±0.9 Gy(RBE) even with a single rescanning (1×PCR). Using 4×PCR or more achieved adequate target coverage (CTV-D95 = 46.6±0.3 Gy(RBE) for ungated 4×PCR) and excellent dose homogeneity (homogeneity index = 1.0±0.2% for ungated 4×PCR). Applying respiratory gating, percentage of lung receiving at least 20 Gy(RBE) (lung-V20) and heart maximal dose, averaged over all patients, significantly decreased by 12% (p<0.05) and 13% (p<0.05), respectively.
Conclusions: Four or more PCR during PBS-CIRT improved dose conformation to moving lung tumors without gating. The use of a respiratory-gated strategy in combination with PCR reduced excessive doses to OARs.
書誌情報 Radiation Oncology (Online only URL:http://www.ro-journal.com/)

巻 9, p. 238-1-238-9, 発行日 2014-11
出版者
出版者 BioMed Central
ISSN
収録物識別子タイプ ISSN
収録物識別子 1748-717X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:43:04.425327
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3