A model-based analysis of a simplified beam-specific dose output in proton therapy with a single-ring wobbling system.

https://repo.qst.go.jp/records/47164
https://repo.qst.go.jp/records/47164
7833aa86-6799-4b95-9576-471d15f1e96e
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-07-22
タイトル
タイトル A model-based analysis of a simplified beam-specific dose output in proton therapy with a single-ring wobbling system.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kase, Yuki

× Kase, Yuki

WEKO 471286

Kase, Yuki

Search repository
Yamashita, Haruo

× Yamashita, Haruo

WEKO 471287

Yamashita, Haruo

Search repository
Numano, Masumi

× Numano, Masumi

WEKO 471288

Numano, Masumi

Search repository
Sakama, Makoto

× Sakama, Makoto

WEKO 471289

Sakama, Makoto

Search repository
Mizota, Manabu

× Mizota, Manabu

WEKO 471290

Mizota, Manabu

Search repository
Maeda, Yoshikazu

× Maeda, Yoshikazu

WEKO 471291

Maeda, Yoshikazu

Search repository
Tameshige, Yuji

× Tameshige, Yuji

WEKO 471292

Tameshige, Yuji

Search repository
Murayama, Shigeyuki

× Murayama, Shigeyuki

WEKO 471293

Murayama, Shigeyuki

Search repository
山下 晴男

× 山下 晴男

WEKO 471294

en 山下 晴男

Search repository
坂間 誠

× 坂間 誠

WEKO 471295

en 坂間 誠

Search repository
溝田 学

× 溝田 学

WEKO 471296

en 溝田 学

Search repository
前田 嘉一

× 前田 嘉一

WEKO 471297

en 前田 嘉一

Search repository
村山 重行

× 村山 重行

WEKO 471298

en 村山 重行

Search repository
抄録
内容記述タイプ Abstract
内容記述 In radiation therapy, it is necessary to preset a monitor unit in an irradiation control system to deliver a prescribed absolute dose to a reference point in the planning target volume. The purpose of this study was to develop a model-based monitor unit calculation method for proton-beam therapy with a single-ring wobbling system. The absorbed dose at a calibration point per monitor unit had been measured for each beam-specific measurement condition without a patient-specific collimator or range compensator before proton therapeutic irradiation at Shizuoka Cancer Center. In this paper, we propose a simplified dose output model to obtain the output ratio between a beam-specific dose and a reference field dose, from which a monitor unit for the proton treatment could be derived without beam-specific measurements. The model parameters were determined to fit some typical data measured in a proton treatment room, called a Gantry 1 course. Then, the model calculation was compared with 5456 dose output ratios that had been measured for 150-, 190- and 220 MeV therapeutic proton beams in two treatment rooms over the past decade. The mean value and standard deviation of the difference between the measurement and the model calculation were respectively 0.00% and 0.27% for the Gantry 1 course, and -0.25% and 0.35% for the Gantry 2 course. The model calculation was in good agreement with the measured beam-specific doses, within 1%, except for conditions less frequently used for treatment. The small variation for the various beam conditions shows the high long-term reproducibility of the measurement and high degree of compatibility of the two treatment rooms. Therefore, the model was expected to assure the setting value of the dose monitor for treatment, to save the effort required for beam-specific measurement, and to predict the dose output for new beam conditions in the future.
書誌情報 Physics in medicine and biology

巻 60, 号 1, p. 359-374, 発行日 2015-01
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
PubMed番号
識別子タイプ PMID
関連識別子 25503686
DOI
識別子タイプ DOI
関連識別子 10.1088/0031-9155/60/1/359
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:43:10.189942
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3