  1. 原著論文

Feasibility of a brain-dedicated PET-MRI system using four-layer DOI detectors integrated with an RF head coil

https://repo.qst.go.jp/records/47094
https://repo.qst.go.jp/records/47094
66760334-99b9-4586-b673-65bdd20e83cf
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-04-20
タイトル
タイトル Feasibility of a brain-dedicated PET-MRI system using four-layer DOI detectors integrated with an RF head coil
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 470406

Nishikido, Fumihiko

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 470407

Obata, Takayuki

Search repository
Shimizu, Kodai

× Shimizu, Kodai

WEKO 470408

Shimizu, Kodai

Search repository
Suga, Mikio

× Suga, Mikio

WEKO 470409

Suga, Mikio

Search repository
Inadama, Naoko

× Inadama, Naoko

WEKO 470410

Inadama, Naoko

Search repository
Atsushi, Tachibana

× Atsushi, Tachibana

WEKO 470411

Atsushi, Tachibana

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 470412

Yoshida, Eiji

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 470413

Ito, Hiroshi

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 470414

Yamaya, Taiga

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 470415

en 錦戸 文彦

Search repository
小畠 隆行

× 小畠 隆行

WEKO 470416

en 小畠 隆行

Search repository
清水 浩大

× 清水 浩大

WEKO 470417

en 清水 浩大

Search repository
菅 幹生

× 菅 幹生

WEKO 470418

en 菅 幹生

Search repository
稲玉 直子

× 稲玉 直子

WEKO 470419

en 稲玉 直子

Search repository
橘 篤志

× 橘 篤志

WEKO 470420

en 橘 篤志

Search repository
吉田 英治

× 吉田 英治

WEKO 470421

en 吉田 英治

Search repository
伊藤 浩

× 伊藤 浩

WEKO 470422

en 伊藤 浩

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 470423

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 We are developing a PET-MRI system which consists of PET detectors integrated with the head coil of the MRI in order to realize high spatial resolution and high sensitivity in simultaneous measurements. In the PET-MRI system, the PET detectors which consist of a scintillator block, photo-detectors and front-end circuits with four-layer depth-of-interaction (DOI) encoding capability are placed close to the measured object. Therefore, the proposed system can achieve high sensitivity without degradation of spatial resolution at the edge of the field-of-view due to parallax error thanks to the four-layer DOI capability. In this paper, we fabricated a prototype system which consists of a prototype four-layer DOI-PET detector, a dummy PET detector and a prototype birdcage type head coil. Then we used the prototype system to evaluate the performance of the four-layer DOI-PET detector and the reciprocal influence between the PET detectors and MRI images.
\nThe prototype DOI-PET detector consists of six monolithic multi-pixel photon counter (MPPC) arrays (S11064-050P), a readout circuit board, two scintillator blocks and a copper shielding box. Each scintillator block consists of four layers of Lu1.8Gd0.2SiO5:Ce (LGSO) scintillators and reflectors are inserted between the scintillation crystals. The dummy detector has all these components except the two scintillator blocks. The head coil is dedicated to a 3.0 T MRI (MAGNETOM Verio, Siemens) and the two detectors are mounted in gaps between head coil elements.
\nEnergy resolution and crystal identification performance of the prototype four-layer DOI-PET detector were evaluated with and without MRI measurements by the gradient echo and spin echo methods. We identified crystal elements in all four layers from a 2D flood histogram and energy resolution of 15–18% was obtained for single crystal elements in simultaneous measurements. The difference between the average energy resolutions and photo-peak positions with and without MRI measurements was lower than 0.3 percentage points and 1.7% for all layers. The results indicated that these performances were sufficient as PET detectors for the proposed PET-MRI system and there was no influence from the MRI measurements on the PET imaging in the simultaneous measurements. The signal-to-noise ratio of the MRI image and static magnetic field of the MRI were also evaluated with and without measurements of the PET detectors. The maximum decrease of the static magnetic field due to the LGSO scintillators was approximately 1 ppm. The signal-to-noise ratio decreased from 242.80 without the PET detector to 44.948 in simultaneous measurements.
書誌情報 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

巻 756, p. 6-13, 発行日 2014-06
出版者
出版者 ELSEVIER
DOI
識別子タイプ DOI
関連識別子 DOI: 10.1016/j.nima.2014.04.034
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:43:58.930887
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3