ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "fdbf8c91-fe90-4e53-9499-d030c9958abd"}, "_deposit": {"created_by": 1, "id": "47075", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47075"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047075", "sets": ["1"]}, "author_link": ["470140", "470144", "470146", "470141", "470143", "470145", "470142"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "343", "bibliographicPageStart": "333", "bibliographicVolumeNumber": "202", "bibliographic_titles": [{"bibliographic_title": "Euphytica"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We investigated the effect of tissue source selection in combination with ion beam irradiation on generating flower-color mutants in Chrysanthemum morifolium. Flower color mutation in the chrysanthemum cultivar YoMystery (purple flowers) was used as an index to estimate mutation frequency and the spectrum of mutations. Somaclones regenerated from petal and leaf tissues and ion-beam irradiated clones derived from the two tissues were analyzed for stem length and flower color mutation. Three Gy of argon ion beams was regarded as an appropriate dose for irradiation because the resulting color mutants maintained an adequate stem length suitable for commercial use even with high mutation frequencies. Statistical analysis of 7,258 individuals from three separate experiments revealed that (1) somaclones from petal tissue had a higher mutation frequency (2.91 %, r = 0.55) than leaf somaclones (2.01 %, r = 0.26); (2) the effect of tissue source on the frequency of flower color mutations was significantly enhanced when combined with ion-beam irradiation in that the mutation frequency of ion-beam irradiated petal clones was 6.47 % (r = 0.77), whereas that of ion-beam irradiated leaf clones was 3.89 % (r = 0.52); and (3) the spectrum of carotenoid color mutations was remarkably increased by ion-beam irradiation in that both leaf and petal ion-beam irradiated clones had brown, red and yellow flowers in contrast to the soma clones that only produced yellow flowers. These results suggest that intentional or directed induction of flower color mutants with practical value is possible by combining tissue source selection with ion beam irradiation.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Apringer"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s10681-014-1220-3", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0014-2336", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岡村, 正愛"}], "nameIdentifiers": [{"nameIdentifier": "470140", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshihiro, Hase"}], "nameIdentifiers": [{"nameIdentifier": "470141", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古澤, 佳也"}], "nameIdentifiers": [{"nameIdentifier": "470142", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田中, 淳"}], "nameIdentifiers": [{"nameIdentifier": "470143", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡村 正愛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "470144", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古澤 佳也", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "470145", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田中 淳", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "470146", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Tissue-dependent somaclonal mutation frequencies and spectra enhanced by ion beam irradiation in chrysanthemum", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Tissue-dependent somaclonal mutation frequencies and spectra enhanced by ion beam irradiation in chrysanthemum"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47075", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-04-07"}, "publish_date": "2015-04-07", "publish_status": "0", "recid": "47075", "relation": {}, "relation_version_is_last": true, "title": ["Tissue-dependent somaclonal mutation frequencies and spectra enhanced by ion beam irradiation in chrysanthemum"], "weko_shared_id": -1}
  1. 原著論文

Tissue-dependent somaclonal mutation frequencies and spectra enhanced by ion beam irradiation in chrysanthemum

https://repo.qst.go.jp/records/47075
https://repo.qst.go.jp/records/47075
541693f8-17f5-4ecf-ac37-069c766f3777
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-04-07
タイトル
タイトル Tissue-dependent somaclonal mutation frequencies and spectra enhanced by ion beam irradiation in chrysanthemum
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 岡村, 正愛

× 岡村, 正愛

WEKO 470140

岡村, 正愛

Search repository
Yoshihiro, Hase

× Yoshihiro, Hase

WEKO 470141

Yoshihiro, Hase

Search repository
古澤, 佳也

× 古澤, 佳也

WEKO 470142

古澤, 佳也

Search repository
田中, 淳

× 田中, 淳

WEKO 470143

田中, 淳

Search repository
岡村 正愛

× 岡村 正愛

WEKO 470144

en 岡村 正愛

Search repository
古澤 佳也

× 古澤 佳也

WEKO 470145

en 古澤 佳也

Search repository
田中 淳

× 田中 淳

WEKO 470146

en 田中 淳

Search repository
抄録
内容記述タイプ Abstract
内容記述 We investigated the effect of tissue source selection in combination with ion beam irradiation on generating flower-color mutants in Chrysanthemum morifolium. Flower color mutation in the chrysanthemum cultivar YoMystery (purple flowers) was used as an index to estimate mutation frequency and the spectrum of mutations. Somaclones regenerated from petal and leaf tissues and ion-beam irradiated clones derived from the two tissues were analyzed for stem length and flower color mutation. Three Gy of argon ion beams was regarded as an appropriate dose for irradiation because the resulting color mutants maintained an adequate stem length suitable for commercial use even with high mutation frequencies. Statistical analysis of 7,258 individuals from three separate experiments revealed that (1) somaclones from petal tissue had a higher mutation frequency (2.91 %, r = 0.55) than leaf somaclones (2.01 %, r = 0.26); (2) the effect of tissue source on the frequency of flower color mutations was significantly enhanced when combined with ion-beam irradiation in that the mutation frequency of ion-beam irradiated petal clones was 6.47 % (r = 0.77), whereas that of ion-beam irradiated leaf clones was 3.89 % (r = 0.52); and (3) the spectrum of carotenoid color mutations was remarkably increased by ion-beam irradiation in that both leaf and petal ion-beam irradiated clones had brown, red and yellow flowers in contrast to the soma clones that only produced yellow flowers. These results suggest that intentional or directed induction of flower color mutants with practical value is possible by combining tissue source selection with ion beam irradiation.
書誌情報 Euphytica

巻 202, 号 3, p. 333-343, 発行日 2015-04
出版者
出版者 Apringer
ISSN
収録物識別子タイプ ISSN
収録物識別子 0014-2336
DOI
識別子タイプ DOI
関連識別子 10.1007/s10681-014-1220-3
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:44:13.077098
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3