WEKO3
アイテム
Biological Effectiveness of Carbon-Ion Radiation on Various Human Breast Cancer Cell Lines
https://repo.qst.go.jp/records/47063
https://repo.qst.go.jp/records/470631e5ba838-9aaf-455d-8441-ebf98b93c23e
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-25 | |||||
タイトル | ||||||
タイトル | Biological Effectiveness of Carbon-Ion Radiation on Various Human Breast Cancer Cell Lines | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Karasawa, Kumiko
× Karasawa, Kumiko× Fujita, Mayumi× Shoji, Yoshimi× Horimoto, Yoshiya× Inoue, Tatsuya× Imai, Takashi× 唐澤 久美子× 藤田 真由美× 荘司 好美× 今井 高志 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Introduction: Carbon-ion radiotherapy (C-ion RT) is known as a highly effective local treatment and its relative biological effectiveness (RBE) has been valuated for various types of malignant tumors. There are only a few studies on C-ion radio sensitivity in breast cancer, and there has been no evaluation by subtypes. To estimate the impact of C-ion RT for breast cancer, RBE of C-ion beams of various types of human breast cancer cell lines was evaluated by comparison with X-rays. Methods: Six human breast cancer cell lines with different subtypes, Luminal-human epidermal growth factor receptor 2 (HER2)-negative (MCF-7), Luminal-HER2-positive (BT-474), Her2-enriched (SK-BR-3), Basal-like (MDAMB- 468, HCC1937) and ductal carcinoma in situ (MCF10DCIS.com) were used. Radio sensitivities were assessed with survival curves created from colony-forming assay (CFA) and high-density surviving assay (HDS). An X-ray generator was used with 200 kV, 20 mA. The Heavy Ion Medical Accelerator in Chiba (HIMAC) was used for C-ion irradiation, with 290 MeV/u, mono-peak, linear energy transfer (LET) of 80 KeV/μm Results: CFA was not suitable for BT474, SK-BR-3, MDA-MB-468, and HCC1937 because of their low plating efficiency. The differences between the D10 values on HDS were large with X-ray, and the survival curve shoulders for MCF7, MDA-MB-468, and MCF10DCIS.com were wide. On the other hand, the differences between the D10 values were small with C-ion beams, and the survival curves were linear without shoulders for all cell lines except a small shoulder with MCF10DCIS.com. The RBE value of C-ion beams was 2.3 to 3.6, median 2.9 in all cell lines by CFA and HDS. Conclusion: RBE around 3 by C-ion beams was seen in many types of ductal cancer. The small survival curve shoulder on MCF10DCIS.com suggested that non invasive ductal carcinoma is relatively more resistant than invasive cancer. |
|||||
書誌情報 |
Journal of Cell Science & Therapy 巻 5, 号 5, p. 1000180, 発行日 2014-09 |
|||||
出版者 | ||||||
出版者 | OMICS Publishing Group | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2157-7013 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.4172/2157-7013.1000180 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.4172/2157-7013.1000180 | |||||
関連名称 | http://dx.doi.org/10.4172/2157-7013.1000180 |