Sensitivity booster for DOI-PET scanner by utilizing Compton scattering events between detector blocks

https://repo.qst.go.jp/records/47000
https://repo.qst.go.jp/records/47000
b606a592-e313-4483-8036-894a84a9fd1c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-12-16
タイトル
タイトル Sensitivity booster for DOI-PET scanner by utilizing Compton scattering events between detector blocks
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshida, Eiji

× Yoshida, Eiji

WEKO 469164

Yoshida, Eiji

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 469165

Tashima, Hideaki

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 469166

Yamaya, Taiga

Search repository
吉田 英治

× 吉田 英治

WEKO 469167

en 吉田 英治

Search repository
田島 英朗

× 田島 英朗

WEKO 469168

en 田島 英朗

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 469169

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 In a conventional PET scanner, coincidence events are measured with a limited energy window for detection of photoelectric events in order to reject Compton scatter events that occur in a patient, but Compton scatter events caused in detector crystals are also rejected. Scatter events within the patient causes scatter coincidences, but inter crystal scattering (ICS) events have useful information for determining an activity distribution. Some researchers have reported the feasibility of PET scanners based on a Compton camera for tracing ICS into the detector. However, these scanners require expensive semiconductor detectors for high-energy resolution. In the Anger-type block detector, single photons interacting with multiple detectors can be obtained for each interacting position and complete information can be gotten just as for photoelectric events in the single detector. ICS events in the single detector have been used to get coincidence, but single photons interacting with multiple detectors have not been used to get coincidence. In this work, we evaluated effect of sensitivity improvement using Compton kinetics in several types of DOI-PET scanners. The proposed method promises to improve the sensitivity using coincidence events of single photons interacting with multiple detectors, which are identified as the first interaction (FI). FI estimation accuracy can be improved to determine FI validity from the correlation between Compton scatter angles calculated on the coincidence line-of-response. We simulated an animal PET scanner consisting of 42 detectors. Each detector block consists of three types of scintillator crystals (LSO, GSO and GAGG). After the simulation, coincidence events are added as information for several depth-of-interaction (DOI) resolutions. From the simulation results, we concluded the proposed method promises to improve the sensitivity considerably when effective atomic number of a scintillator is low. Also, we showed that FI estimate accuracy is improved, as DOI resolution is high.
書誌情報 Nuclear Instruments & Methods in Physics Research Section A

巻 763, p. 502-509, 発行日 2014-11
出版者
出版者 Elsevier
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2014.07.002
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:45:06.946037
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3