Undoped Polycarbonate for Detection of Environmental Radiation

https://repo.qst.go.jp/records/46992
https://repo.qst.go.jp/records/46992
588d3aff-5823-42dc-af94-d9ed7ff99a48
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-12-16
タイトル
タイトル Undoped Polycarbonate for Detection of Environmental Radiation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakamura, Hidehito

× Nakamura, Hidehito

WEKO 469090

Nakamura, Hidehito

Search repository
Shirakawa, Yoshiyuki

× Shirakawa, Yoshiyuki

WEKO 469091

Shirakawa, Yoshiyuki

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 469092

Kitamura, Hisashi

Search repository
Sato, Nobuhiro

× Sato, Nobuhiro

WEKO 469093

Sato, Nobuhiro

Search repository
Takahashi, Sentaro

× Takahashi, Sentaro

WEKO 469094

Takahashi, Sentaro

Search repository
中村 秀仁

× 中村 秀仁

WEKO 469095

en 中村 秀仁

Search repository
白川 芳幸

× 白川 芳幸

WEKO 469096

en 白川 芳幸

Search repository
北村 尚

× 北村 尚

WEKO 469097

en 北村 尚

Search repository
高橋 千太郎

× 高橋 千太郎

WEKO 469098

en 高橋 千太郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 The enormous area of damage to Japan's Fukushima Daiichi nuclear power plant requires detectors with robust base substrates to monitor high-dose-rate environmental radiation with long- term stability. Undoped aromatic ring polymers have considerable potential as base substrates in radiation detection. Here, we characterise polycarbonate(PC), which has excellent transparency, shock, radiation, and weather resistance, heat tolerance, and anti-abrasion qualities. It has a density of 1.20g/㎤, an excitation of 310nm, and short-wavelength emission with a maximum at 350-nm. By taking into account its emmision, we detemined an effective refractive index of 1.64.PC has a light yield that is 0.67 times that of undoped poly (ethylene terephthalate). These results reveal that readily available PC is an effective base substrate for use in large-area radiation detectors for the nuclear power plant recovery proccess.
書誌情報 Japanese Journal of Health Physics

巻 49, 号 2, p. 98-101, 発行日 2014-06
出版者
出版者 Japan Health Physics Society
ISSN
収録物識別子タイプ ISSN
収録物識別子 0367-6110
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:45:12.495428
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3