Verification of shielding effect by the water-filled materials for space radiation in the International Space Station using passive dosimeters
https://repo.qst.go.jp/records/46981
https://repo.qst.go.jp/records/46981e11374b9-a220-446a-aba6-cbd848476098
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-12-09 | |||||
タイトル | ||||||
タイトル | Verification of shielding effect by the water-filled materials for space radiation in the International Space Station using passive dosimeters | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kodaira, Satoshi
× Kodaira, Satoshi× Tolochek, R.V.× Iva, Ambrozova× Kawashima, Hajime× Yasuda, N.× Kurano, Mieko× Kitamura, Hisashi× Uchihori, Yukio× Kobayashi, Ikuo× Hakamada, H.× Suzuki, A.× Kartsev, I.S.× Yarmanova, E.N.× Nikolaev, I.V.× Shurshakov, Vyacheslav× 小平 聡× イバ アンブロツォヴァ× 川嶋 元× 蔵野 美恵子× 北村 尚× 内堀 幸夫× 小林 育夫× Shurshakov Vyacheslav |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The dose reduction effects for space radiation by installation of water shielding material (“protective curtain”) of a stack board consisting of the hygienic wipes and towels have been experimentally evaluated in the International Space Station by using passive dosimeters. The averaged water thickness of the protective curtain was 6.3 g/cm2. The passive dosimeters consisted of a combination of thermoluminescent detectors (TLDs) and plastic nuclear track detectors (PNTDs). Totally 12 passive dosimeter packages were installed in the Russian Service Module during late 2010. Half of the packages were located at the protective curtain surface and the other half were at the crew cabin wall behind or aside the protective curtain. The mean absorbed dose and dose equivalent rates are measured to be 327 uGy/day and 821 uSv/day for the unprotected packages and 224 uGy/day and 575 uSv/day for the protected packages, respectively. The observed dose reduction rate with protective curtain was found to be 37 ± 7% in dose equivalent, which was consistent with the calculation in the spherical water phantom by PHITS. The contributions due to low and high LET particles were found to be comparable in observed dose reduction rate. The protective curtain would be effective shielding material for not only trapped particles (several 10 MeV) but also for low energy galactic cosmic rays (several 100 MeV/n). The properly utilized protective curtain will effectively reduce the radiation dose for crew living in space station and prolong long-term mission in the future. | |||||