ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Adaptive radiotherapy based on the daily regression of a tumor in carbon-ion beam irradiation

https://repo.qst.go.jp/records/46906
https://repo.qst.go.jp/records/46906
bdeb51a1-733f-47b9-8ea4-2a71c0c11a25
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-11-06
タイトル
タイトル Adaptive radiotherapy based on the daily regression of a tumor in carbon-ion beam irradiation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 nagano, Ai

× nagano, Ai

WEKO 468066

nagano, Ai

Search repository
Minohara, Shinichi

× Minohara, Shinichi

WEKO 468067

Minohara, Shinichi

Search repository
Kato, Shingo

× Kato, Shingo

WEKO 468068

Kato, Shingo

Search repository
Kiyohara, Hiroki

× Kiyohara, Hiroki

WEKO 468069

Kiyohara, Hiroki

Search repository
Ando, Ken

× Ando, Ken

WEKO 468070

Ando, Ken

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 468071

en 蓑原 伸一

Search repository
加藤 眞吾

× 加藤 眞吾

WEKO 468072

en 加藤 眞吾

Search repository
清原 浩樹

× 清原 浩樹

WEKO 468073

en 清原 浩樹

Search repository
安藤 謙

× 安藤 謙

WEKO 468074

en 安藤 謙

Search repository
抄録
内容記述タイプ Abstract
内容記述 We propose a new application of adaptive radiotherapy using a scanning beam, taking into account the daily regression of a tumor. No patient-specific hardware (such as collimators and compensating filters) is needed for the scanning technique; thus, it allows re-planning immediately before each fractional irradiation using the sophisticated conformations of dose distributions. We retrospectively modeled the tumor volume regression curves as a function of the dose from the CT images which were taken three times during the treatment course. The daily shape of the tumor was mathematically interpolated assuming constant continuity of the tumor deformation. We simulated the adaptive radiotherapy by optimizing the dose distribution on the estimated daily tumor volume for every fraction. The dose–volume histogram (DVH) for the organ at risk in the adaptive radiotherapy was compared with that of the current clinical protocol. We performed analysis using the CT images of cervical cancer patients who received carbon-ion radiotherapy in broad-beam irradiation. The DVH for the rectum and the sigmoid colon was improved by adaptive radiotherapy considering the inter-fractional tumor regression. The result shows that this approach has possible advantages.
書誌情報 Physics in Medicine and Biology

巻 57, 号 24, p. 8343-8356, 発行日 2012-12
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:46:12.493345
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3