ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Development of new optical imaging systems of oxygen metabolism and simultaneous measurement in hemodynamic changes using awake mice.

https://repo.qst.go.jp/records/46891
https://repo.qst.go.jp/records/46891
12b97c8a-a96b-40f3-bac2-2d1dc069820d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-10-28
タイトル
タイトル Development of new optical imaging systems of oxygen metabolism and simultaneous measurement in hemodynamic changes using awake mice.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takuwa, Hiroyuki

× Takuwa, Hiroyuki

WEKO 467919

Takuwa, Hiroyuki

Search repository
Matsuura, Tetsuya

× Matsuura, Tetsuya

WEKO 467920

Matsuura, Tetsuya

Search repository
Nishino, Asuka

× Nishino, Asuka

WEKO 467921

Nishino, Asuka

Search repository
Sakata, Kazumi

× Sakata, Kazumi

WEKO 467922

Sakata, Kazumi

Search repository
Tajima, Yosuke

× Tajima, Yosuke

WEKO 467923

Tajima, Yosuke

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 467924

Ito, Hiroshi

Search repository
田桑 弘之

× 田桑 弘之

WEKO 467925

en 田桑 弘之

Search repository
松浦 哲也

× 松浦 哲也

WEKO 467926

en 松浦 哲也

Search repository
西野 明日香

× 西野 明日香

WEKO 467927

en 西野 明日香

Search repository
田島 洋佑

× 田島 洋佑

WEKO 467928

en 田島 洋佑

Search repository
伊藤 浩

× 伊藤 浩

WEKO 467929

en 伊藤 浩

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background:PET allows the measurement of CBF, CBV and CMRO2 in human and plays an important role in the diagnosis of pathologic conditions and clinical research. On the other hand, in animal studies, there is no optical imaging system for evaluating changes in CBF and CBV, and oxygen metabolism, from the same brain area under awake condition.
New method:In the present study, we developed a simultaneous measurement system of LSI and IOSI, which was verified by LDF. Moreover, to evaluate oxygen metabolism, FAI was performed from the same brain area as LSI and IOSI measurements.
Results:The change in CBF according to LSI was correlated with that by LDF. Similarly, the change in CBV obtained by IOSI was also correlated with RBC concentration change measured by LDF. The change in oxygen metabolism by FAI was associated with that in CBF obtained by LSI, although the change in CBF was greater than that in oxygen metabolism.
Comparison with existing method(s): We revealed that the relationship between oxygen metabolism and CBF as measured by our system was in good agreement with the relationship between CMRO2 and CBF in human PET studies.
Conclusions:Our measurement system of CBF, CBV and oxygen metabolism is not only useful for studying neurovascular coupling, but also easily corroborates human PET studies.
書誌情報 Journal of neuroscience methods

巻 237, p. 9-15, 発行日 2014-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0165-0270
PubMed番号
識別子タイプ PMID
関連識別子 25192830
DOI
識別子タイプ DOI
関連識別子 10.1016/j.jneumeth.2014.08.022
戻る
0
views
See details
Views