ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Response of a Plate-type Thermoluminescence Dosimeter to a Therapeutic Carbon Beam

https://repo.qst.go.jp/records/46890
https://repo.qst.go.jp/records/46890
98a8e7b0-db80-476c-906b-5297205ad407
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-10-28
タイトル
タイトル Response of a Plate-type Thermoluminescence Dosimeter to a Therapeutic Carbon Beam
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Koba, Yusuke

× Koba, Yusuke

WEKO 467909

Koba, Yusuke

Search repository
Fukuda, Shigekazu

× Fukuda, Shigekazu

WEKO 467910

Fukuda, Shigekazu

Search repository
Shinsho, Kiyomitsu

× Shinsho, Kiyomitsu

WEKO 467911

Shinsho, Kiyomitsu

Search repository
Wakabayashi, Genichiro

× Wakabayashi, Genichiro

WEKO 467912

Wakabayashi, Genichiro

Search repository
Tamatsu, Satoshi

× Tamatsu, Satoshi

WEKO 467913

Tamatsu, Satoshi

Search repository
古場 裕介

× 古場 裕介

WEKO 467914

en 古場 裕介

Search repository
福田 茂一

× 福田 茂一

WEKO 467915

en 福田 茂一

Search repository
眞正 浄光

× 眞正 浄光

WEKO 467916

en 眞正 浄光

Search repository
若林 源一郎

× 若林 源一郎

WEKO 467917

en 若林 源一郎

Search repository
玉津 早駿

× 玉津 早駿

WEKO 467918

en 玉津 早駿

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to measure the three-dimensional dose distribution in X-ray radiotherapy, we developed a plate-type thermoluminescence dosimeter (TLD) using the TL phosphor Li3B7O12:Cu, which has Z eff = 7.42 and a density of 1.01 gcm-3. This detector was expected on useful application in advanced X-ray radiotherapies such as intensity-modulated ratiation therapy (IMRT) etc., because it can obtain 3D dose measurements simply and quickly with a single exposure. In this paper, we report the response of this plate-type TLD to a therapeutic carbon beam at the Heavy Ion Medical Accelerator in Chiba (HIMAC). Using a plate heater and charge coupled device (CCD) camera, we captured thermoluminescence images of plate-type TLDs irradiated by a therapeutic carbon beam. The TL intensity was measured at each water equivalent depth and compared with output of the ionization chamber. The relative TL efficiency of this TLD as 60Co gamma-ray equivalent decreased gradually with increasing dose-averaged linear-energy-transfer (LET), reaching about 20% at the Bragg peak of 290 MeV/u carbon ions.
書誌情報 Journal of the Korean Physical Society

巻 63, 号 7, p. 1432-1436, 発行日 2013-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 0374-4884
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:46:24.230879
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3