Occupational exposure to Austrian rocks used as radon spa sources in Japan

https://repo.qst.go.jp/records/46874
https://repo.qst.go.jp/records/46874
337318fd-e919-478c-90e4-ee457966ebc0
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-10-21
タイトル
タイトル Occupational exposure to Austrian rocks used as radon spa sources in Japan
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 467685

Iwaoka, Kazuki

Search repository
Tabe, Hiroyuki

× Tabe, Hiroyuki

WEKO 467686

Tabe, Hiroyuki

Search repository
Ishikawa, Tetsuo

× Ishikawa, Tetsuo

WEKO 467687

Ishikawa, Tetsuo

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 467688

Tokonami, Shinji

Search repository
Yonehara, Hidenori

× Yonehara, Hidenori

WEKO 467689

Yonehara, Hidenori

Search repository
岩岡 和輝

× 岩岡 和輝

WEKO 467690

en 岩岡 和輝

Search repository
田部 裕章

× 田部 裕章

WEKO 467691

en 田部 裕章

Search repository
石川 徹夫

× 石川 徹夫

WEKO 467692

en 石川 徹夫

Search repository
米原 英典

× 米原 英典

WEKO 467693

en 米原 英典

Search repository
抄録
内容記述タイプ Abstract
内容記述 The activity concentrations of natural radionuclides in Austrian rocks used as artificial radon spa sources in Japan as well as the 222Rn and 220Rn concentrations, and the ambient dose rates at work sites in a dealership for the Austrian rocks were measured, and the dose estimation for the worker was conducted. The activity concentrations of 226Ra, 228Ra, and 40K in the Austrian rocks were found to be less than the critical values in the International Atomic Energy Agency safety guide. The ambient dose rates and 222Rn concentrations at the work sites were higher than that in the background. The 220Rn concentrations in all sites were less than the limit of determination. The value of the total effective dose to the worker was 560 uSv y-1, which was less than the intervention exemption level (1000 uSv y-1) given in the International Commission on Radiological Protection Publication 82.
書誌情報 Radiation Emergency Medicine

巻 2, 号 1, p. 23-26, 発行日 2013-02
ISSN
収録物識別子タイプ ISSN
収録物識別子 2186-8026
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:46:35.100298
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3