WEKO3
アイテム
Simultaneous sampling of indoor and outdoor airborne radioactivity after the Fukushima Daiichi Nuclear Power Plant accident.
https://repo.qst.go.jp/records/46870
https://repo.qst.go.jp/records/46870447844e1-585e-4ee0-948b-1a0c6612e067
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-10-21 | |||||
タイトル | ||||||
タイトル | Simultaneous sampling of indoor and outdoor airborne radioactivity after the Fukushima Daiichi Nuclear Power Plant accident. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ishikawa, Tetsuo
× Ishikawa, Tetsuo× Sorimachi, Atsuyuki× Arae, Hideki× Kumar, Sahoo Sarata× Janik, Miroslaw× Hosoda, Masahiro× Tokonami, Shinji× 新江 秀樹× サフー サラタ クマール× ミロソラフ ヤニック |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Several studies have estimated inhalation doses for the public due to the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. Most of them were based on measurement of radioactivity in outdoor air and included the assumption that people stayed outdoors all day. Although this assumption gives a conservative estimate, it is not realistic. The "air decontamination factor" (ratio of indoor to outdoor air radionuclide concentrations) was estimated from simultaneous sampling of radioactivity in both inside and outside air of one building. The building was a workplace and located at the National Institute of Radiological Sciences (NIRS) in Chiba Prefecture, Japan. Aerosol-associated radioactive materials in air were collected onto filters and the filters were analyzed by gamma spectrometry at NIRS. The filter sampling was started on March 15, 2011 and was continued for more than a year. Several radionuclides such as (131)I, (134)Cs and (137)Cs were found by measuring the filters with a germanium detector. The air decontamination factor was around 0.64 for particulate (131)I and 0.58 for (137)Cs. These values could give implications for the ratio of indoor to outdoor radionuclide concentrations after the FDNPP accident for a similar type of buildings. | |||||
書誌情報 |
Environmental science & technology 巻 48, 号 4, p. 2430-2435, 発行日 2014-02 |
|||||
出版者 | ||||||
出版者 | American Chemical Society | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0013-936X | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 24450729 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1021/es404691m |