  1. 原著論文

Reduction method for intrinsic random coincidence events from (176)Lu in low activity PET imaging.

https://repo.qst.go.jp/records/46815
https://repo.qst.go.jp/records/46815
daaf5fee-5737-4073-8048-4723cd97763a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-09-01
タイトル
タイトル Reduction method for intrinsic random coincidence events from (176)Lu in low activity PET imaging.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshida, Eiji

× Yoshida, Eiji

WEKO 467010

Yoshida, Eiji

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 467011

Tashima, Hideaki

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 467012

Nishikido, Fumihiko

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 467013

Murayama, Hideo

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 467014

Yamaya, Taiga

Search repository
吉田 英治

× 吉田 英治

WEKO 467015

en 吉田 英治

Search repository
田島 英朗

× 田島 英朗

WEKO 467016

en 田島 英朗

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 467017

en 錦戸 文彦

Search repository
村山 秀雄

× 村山 秀雄

WEKO 467018

en 村山 秀雄

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 467019

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 For clinical studies, the effects of the intrinsic radioactivity of lutetium-based scintillators such as LSO used in PET imaging can be ignored within a narrow energy window. However, the intrinsic radioactivity becomes problematic when used in low-count-rate situations such as gene expression imaging or in-beam PET imaging. Time-of-flight (TOF) measurement capability promises not only to improve PET image quality, but also to reduce intrinsic random coincidences. On the other hand, we have developed a new reduction method for intrinsic random coincidence events based on multiple-coincidence information. Without the energy window, an intrinsic random coincidence is detected simultaneously with an intrinsic true coincidence as a multiple coincidence. The multiple-coincidence events can serve as a guide to identification of the intrinsic coincidences. After rejection of multiple-coincidence events detected with a wide energy window, data obtained included a few intrinsic random and many intrinsic true coincidence events. We analyzed the effect of intrinsic radioactivity and used Monte Carlo simulation to test both the TOF-based method and the developed multiple-coincidence-based (MC-based) method for a whole-body LSO-PET scanner. Using the TOF- and MC-based reduction methods separately, we could reduce the intrinsic random coincidence rates by 77 and 30 %, respectively. Also, the intrinsic random coincidence rate could be reduced by 84 % when the TOF+MC reduction methods were applied. The developed MC-based method showed reduced number of the intrinsic random coincidence events, but the reduction performance was limited compared to that of the TOF-based reduction method.
書誌情報 Radiological physics and technology

巻 7, 号 2, p. 235-245, 発行日 2014-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
PubMed番号
識別子タイプ PMID
関連識別子 24496884
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-014-0258-1
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:47:16.922661
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3