Monte Carlo simulation of efficient data acquisition for an entire-body PET scanner
https://repo.qst.go.jp/records/46792
https://repo.qst.go.jp/records/4679253d08822-654b-4cd5-8994-0d4a5ed1d1f7
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-07-28 | |||||
タイトル | ||||||
タイトル | Monte Carlo simulation of efficient data acquisition for an entire-body PET scanner | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
ISMET, ISNAINI
× ISMET, ISNAINI× Obi, Takashi× Yoshida, Eiji× Yamaya, Taiga× イスメット イスナイニ× 小尾 高史× 吉田 英治× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Conventional PET scanners can image the whole body using many bed positions. On the other hand, an entire-body PET scanner with an extended axial FOV, which can trace whole-body uptake images at the same time and improve sensitivity dynamically, has been desired. The entire-body PET scanner would have to process a large amount of data effectively. As a result, the entire-body PET scanner has high dead time at a multiplex detector grouping process. Also, the entire-body PET scanner has many oblique line-of-responses. In this work, we study an efficient data acquisition for the entire-body PET scanner using the Monte Carlo simulation. The simulated entire-body PET scanner based on depth-of-interaction detectors has a 2016-mm axial field-of-view (FOV) and an 80-cm ring diameter. Since the entire-body PET scanner has higher single data loss than a conventional PET scanner at grouping circuits, the NECR of the entire-body PET scanner decreases. But, single data loss is mitigated by separating the axially arranged detector into multiple parts. Our choice of 3 groups of axially-arranged detectors has shown to increase the peak NECR by 41%. An appropriate choice of maximum ring difference (MRD) will also maintain the same high performance of sensitivity and high peak NECR while at the same time reduces the data size. The extremely-oblique line of response for large axial FOV does not contribute much to the performance of the scanner. The total sensitivity with full MRD increased only 15% than that with about half MRD. The peak NECR was saturated at about half MRD. The entire-body PET scanner promises to provide a large axial FOV and to have sufficient performance values without using the full data. | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research A 巻 751, 号 1, p. 36-40, 発行日 2014-04 |
|||||
出版者 | ||||||
出版者 | ELSEVIER | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.1016/j.nima.2014.02.051 | |||||
関連名称 | http://dx.doi.org/10.1016/j.nima.2014.02.051 |