ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Ultra-trace plutonium determination in small volume seawater by sector-field inductively coupled plasma mass spectrometry with application to Fukushima seawater samples

https://repo.qst.go.jp/records/46785
https://repo.qst.go.jp/records/46785
8c501bc4-dd4a-407d-a3f8-fb8ffa9257ae
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-07-22
タイトル
タイトル Ultra-trace plutonium determination in small volume seawater by sector-field inductively coupled plasma mass spectrometry with application to Fukushima seawater samples
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 ト, 文庭

× ト, 文庭

WEKO 466626

ト, 文庭

Search repository
鄭, 建

× 鄭, 建

WEKO 466627

鄭, 建

Search repository
青野, 辰雄

× 青野, 辰雄

WEKO 466628

青野, 辰雄

Search repository
田上, 恵子

× 田上, 恵子

WEKO 466629

田上, 恵子

Search repository
内田, 滋夫

× 内田, 滋夫

WEKO 466630

内田, 滋夫

Search repository
et.al

× et.al

WEKO 466631

et.al

Search repository
ト 文庭

× ト 文庭

WEKO 466632

en ト 文庭

Search repository
鄭 建

× 鄭 建

WEKO 466633

en 鄭 建

Search repository
青野 辰雄

× 青野 辰雄

WEKO 466634

en 青野 辰雄

Search repository
田上 恵子

× 田上 恵子

WEKO 466635

en 田上 恵子

Search repository
内田 滋夫

× 内田 滋夫

WEKO 466636

en 内田 滋夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Long-term monitoring of Pu isotopes in seawater is required for assessing Pu contamination in the marine environment from the Fukushima Dai-ichi Nuclear Power Plant accident. In this study, we established an accurate and precise analytical method based on anion-exchange chromatography and SF-ICP-MS. This method was able to determine Pu isotopes in seawater samples with small volumes (20-60 L). The U decontamination factor was 3×107-1×108, which provided sufficient removal of interfering U from the seawater samples. The estimated limits of detection for 239Pu and 240Pu were 0.11 fg mL-1 and 0.08 fg mL-1, respectively, which corresponded to 0.01 mBq m-3 for 239Pu and 0.03 mBq m-3 for 240Pu when a 20 L volume of seawater was measured. We achieved good precision (2.9%) and accuracy (0.8%) for measurement of the 240Pu/239Pu atom ratio in the standard Pu solution with a 239Pu concentration of 11 fg mL-1 and 240Pu concentration of 2.7 fg mL-1. Seawater reference materials were used for the method validation and both the 239+240Pu activities and 240Pu/239Pu atom ratios agreed well with the expected values. Surface and bottom seawater samples collected off Fukushima in the western North Pacific since March 2011 were analyzed. Our results suggested that there was no significant variation of the Pu distribution in seawater in the investigated areas compared to the distribution before the accident.
書誌情報 Journal of Chromatography A

巻 1337, p. 171-178, 発行日 2014-08
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0021-9673
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:47:39.221372
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3