ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Carbon ion radiotherapy for oligo-recurrence in the lung.

https://repo.qst.go.jp/records/46712
https://repo.qst.go.jp/records/46712
3dbee070-2aac-40a3-b9db-439e86b36b19
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-02-03
タイトル
タイトル Carbon ion radiotherapy for oligo-recurrence in the lung.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamamoto, Naoyoshi

× Yamamoto, Naoyoshi

WEKO 465760

Yamamoto, Naoyoshi

Search repository
Nakajima, Mio

× Nakajima, Mio

WEKO 465761

Nakajima, Mio

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 465762

Tsujii, Hirohiko

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 465763

Kamada, Tadashi

Search repository
山本 直敬

× 山本 直敬

WEKO 465764

en 山本 直敬

Search repository
中嶋 美緒

× 中嶋 美緒

WEKO 465765

en 中嶋 美緒

Search repository
辻井 博彦

× 辻井 博彦

WEKO 465766

en 辻井 博彦

Search repository
鎌田 正

× 鎌田 正

WEKO 465767

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 The clinical results after carbon ion radiotherapy for the metastatic lung tumors believed to be in the state of oligo-recurrence were evaluated. One hundred and sixteen lesions in 91 patients with lung cancer metastasis were treated with carbon ion radiotherapy at our institute from April 1997 to February 2011. Regarding the prescribed dose, total dose ranged between 40 gray equivalents (GyE) and 80 GyE, and fraction size ranged from 1 to 16 fractions. After a median followup period of 2.3 years (range, 0.3-13.1 years), the statistical overall survival rate and local control rate were 71.2% and 91.9% at 2 years after treatment, respectively. Treatment-related side effects were not a clinical problem. When classified by the primary organ, there were 49 cases of lung cancer, 20 cases of colorectal cancer, and 22 cases of others. The overall survival rate and local control rate for lung metastasis cases from lung cancer at 2 years after treatment were 81.5% and 92.4%, respectively, and 65.0% and 92.0% regarding lung metastasis from colorectal cancer. Carbon ion beam therapy for the metastatic lung tumors is a safe therapy, and the therapeutic effect is comparable to the outcome obtained from reported surgical resections.
書誌情報 Pulmonary medicine

巻 2013, p. 219746, 発行日 2013-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 2090-1844
PubMed番号
識別子タイプ PMID
関連識別子 23431437
DOI
識別子タイプ DOI
関連識別子 10.1155/2013/219746
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:48:31.735939
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3