ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Rapid estimation of inhaled particle size for internal dose during nuclear emergency medicine

https://repo.qst.go.jp/records/46683
https://repo.qst.go.jp/records/46683
b4c81d3a-717a-42ea-9806-34f2ffb00872
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-12-16
タイトル
タイトル Rapid estimation of inhaled particle size for internal dose during nuclear emergency medicine
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Fukutsu, Kumiko

× Fukutsu, Kumiko

WEKO 465472

Fukutsu, Kumiko

Search repository
Yamada, Yuji

× Yamada, Yuji

WEKO 465473

Yamada, Yuji

Search repository
福津 久美子

× 福津 久美子

WEKO 465474

en 福津 久美子

Search repository
山田 裕司

× 山田 裕司

WEKO 465475

en 山田 裕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 Information on particle size is one of the important factors for internal dose estimation at accidents with airborne radioactive materials. An autoradiography method has been investigated as a technique for the sizing of alpha-emitting particles. Concerning nuclear emergency medicine, the waiting time for dose estimation is limited. For determining the shortest estimation time, the exposure time of autoradiography was examined using 239PuO2 particles captured on HEPA filters. In this study, the effective counting efficiency of tracks produced by alpha
particles was evaluated to be 0.31 by a numerical simulation. The minimum exposure time for 239PuO2 with aerodynamic diameter of 5 µm was found to be only 10 min. When any star-like alpha particle track was not detected after 6 h of exposure, even if the sample had significant radioactivity, the aerodynamic diameter
was assumed to be less than 1 µm. When the radioactivity of 239PuO2 particles detected by autoradiography within 1 h was dominant of total activity, the aerodynamic diameter would be estimated to be over 5 µm. These results indicate that the precise dose estimation is useful for the decision of medical treatment.
書誌情報 Health Physics

巻 105, 号 6, p. 555-560, 発行日 2013-12
出版者
出版者 Lippincott Williams & Wilkins, Inc.
ISSN
収録物識別子タイプ ISSN
収録物識別子 0017-9078
DOI
識別子タイプ DOI
関連識別子 10.1097/JP.0b013e31829e5597
関連サイト
識別子タイプ URI
関連識別子 www.health-physics.com
関連名称 www.health-physics.com
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:48:51.216676
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3