Preliminary study: Color Map of Hepatocellular Carcinoma Using Dynamic Contrast-Enhanced 256-Row Detector CT

https://repo.qst.go.jp/records/46623
https://repo.qst.go.jp/records/46623
fbb479d5-0066-4f6d-aa6f-e3f4afd2cd91
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-11-25
タイトル
タイトル Preliminary study: Color Map of Hepatocellular Carcinoma Using Dynamic Contrast-Enhanced 256-Row Detector CT
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 464799

Mori, Shinichiro

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 464800

Obata, Takayuki

Search repository
Katou, Hirotoshi

× Katou, Hirotoshi

WEKO 464801

Katou, Hirotoshi

Search repository
Kishimoto, Riwa

× Kishimoto, Riwa

WEKO 464802

Kishimoto, Riwa

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 464803

Kandatsu, Susumu

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 464804

Tanada, Shuji

Search repository
Endo, Masahiro

× Endo, Masahiro

WEKO 464805

Endo, Masahiro

Search repository
森 慎一郎

× 森 慎一郎

WEKO 464806

en 森 慎一郎

Search repository
小畠 隆行

× 小畠 隆行

WEKO 464807

en 小畠 隆行

Search repository
加藤 博敏

× 加藤 博敏

WEKO 464808

en 加藤 博敏

Search repository
岸本 理和

× 岸本 理和

WEKO 464809

en 岸本 理和

Search repository
神立 進

× 神立 進

WEKO 464810

en 神立 進

Search repository
棚田 修二

× 棚田 修二

WEKO 464811

en 棚田 修二

Search repository
遠藤 真広

× 遠藤 真広

WEKO 464812

en 遠藤 真広

Search repository
抄録
内容記述タイプ Abstract
内容記述 To distinguish hepatocellular carcinoma (HCC) from normal liver tissue, a color map was made by dynamic contrast-enhanced 256-detector row CT developed at our institute. Dynamic enhanced CT of the liver of three patients with HCC was studied. The CT has 912 (transverse) x 256 (cranio-caudal) elements, each measuring approximately 0.5 mm x 0.5mm at the center of rotation. Scanning for 10 s (1.0 s/rotation) was started 30 s after intravenous injection of contrast medium. The reconstruction increment was 0.62 mm with a time interval of 0.1s and a matrix size of 512 x 512 x 256. Color maps were generated to show the gradient of the regression line of the time-density change. Due to volume acquisition, the 3D color map can be created using continuous 10-s scanning. The densities of the HCC and liver were decreased and increased during scanning, respectively. The HCC was detected clearly in the color map as a downward-sloping region. Dynamic enhanced 256-detector row CT could be useful for detecting malignant tumors in the liver with a short scan time.
書誌情報 European Journal of Radiology

巻 62, 号 2, p. 308-310, 発行日 2007-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0720-048X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:49:34.379513
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3