  1. 原著論文

Measurements of Magnetic Field Harmonics in Superconductor Coil Wound by Surface Winding Technology

https://repo.qst.go.jp/records/46618
https://repo.qst.go.jp/records/46618
3fc1a0f0-f515-4bca-b31f-61deb395d2ff
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-11-06
タイトル
タイトル Measurements of Magnetic Field Harmonics in Superconductor Coil Wound by Surface Winding Technology
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Amemiya, Naoyuki

× Amemiya, Naoyuki

WEKO 464734

Amemiya, Naoyuki

Search repository
Nakamura, Taketsune

× Nakamura, Taketsune

WEKO 464735

Nakamura, Taketsune

Search repository
Ogitsu, Toru

× Ogitsu, Toru

WEKO 464736

Ogitsu, Toru

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 464737

Noda, Kouji

Search repository
et.al

× et.al

WEKO 464738

et.al

Search repository
雨宮 尚之

× 雨宮 尚之

WEKO 464739

en 雨宮 尚之

Search repository
荻津 透

× 荻津 透

WEKO 464740

en 荻津 透

Search repository
野田 耕司

× 野田 耕司

WEKO 464741

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 Magnetic field harmonics (multi-pole component of magnetic field) were measured in a 24-layer coil for a dipole magnet wound with NbTi round wires by using the surface winding technology (direct winding technology). The coil was wound layer by layer, and the magnetic field measurements were carried out by using rotating pick-up coil system, when the 4 layers, 10 layers, 16 layers, 20 layers, and 24 layers of the coil were wound. The measured magnetic field harmonics were compared with theoretical values. The error, which is the difference between the measured value and theoretical one, does not increase substantially with increasing number of wound layers when measured at the center of the coil. Larger errors measured near the coil end should have been caused by the position errors of wires, which was observed visually.
書誌情報 IEEE Transactions on Applied Superconductivity

巻 22, 号 3, p. 9000404-1-9000404-3, 発行日 2012-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 1051-8223
DOI
識別子タイプ DOI
関連識別子 10.1109/tasc.2011.2180295
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:49:37.858733
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3