ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Calibration of CR-39 with atomic force microscope for the measurement of short range tracks from proton-induced target fragmentation reactions

https://repo.qst.go.jp/records/46599
https://repo.qst.go.jp/records/46599
aed26c5e-b908-4bd0-be01-4c310d20d7ee
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-10-01
タイトル
タイトル Calibration of CR-39 with atomic force microscope for the measurement of short range tracks from proton-induced target fragmentation reactions
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 464510

Kodaira, Satoshi

Search repository
Yasuda, Nakahiro

× Yasuda, Nakahiro

WEKO 464511

Yasuda, Nakahiro

Search repository
Konishi, Teruaki

× Konishi, Teruaki

WEKO 464512

Konishi, Teruaki

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 464513

Kitamura, Hisashi

Search repository
Kurano, Mieko

× Kurano, Mieko

WEKO 464514

Kurano, Mieko

Search repository
Kawashima, Hajime

× Kawashima, Hajime

WEKO 464515

Kawashima, Hajime

Search repository
Uchihori, Yukio

× Uchihori, Yukio

WEKO 464516

Uchihori, Yukio

Search repository
Ogura, Kouichi

× Ogura, Kouichi

WEKO 464517

Ogura, Kouichi

Search repository
Benton, Eric

× Benton, Eric

WEKO 464518

Benton, Eric

Search repository
小平 聡

× 小平 聡

WEKO 464519

en 小平 聡

Search repository
小西 輝昭

× 小西 輝昭

WEKO 464520

en 小西 輝昭

Search repository
北村 尚

× 北村 尚

WEKO 464521

en 北村 尚

Search repository
蔵野 美恵子

× 蔵野 美恵子

WEKO 464522

en 蔵野 美恵子

Search repository
川嶋 元

× 川嶋 元

WEKO 464523

en 川嶋 元

Search repository
内堀 幸夫

× 内堀 幸夫

WEKO 464524

en 内堀 幸夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 We studied the track response of CR-39 plastic nuclear track detectors (PNTD) for low (<6 MeV/n) and high (>100 MeV/n) energy heavy ions using the atomic force microscope (AFM). CR-39 PNTD was exposed to several heavy ion beams of different energy at HIMAC (Heavy Ion Medical Accelerator in Chiba). For AFM measurement, the amount of bulk etch was controlled to be &#8764;2 &#956;m in order to avoid etching away of short range tracks. The response data obtained by AFM for &#8764;2 &#956;m bulk etch was in good agreement with data obtained by the conventional optical microscope analysis for larger bulk etch. The response data from low energy beams (stopping near the surface) was also consistent with the data from high energy beams (penetrating the detector) as a function of REL (restricted energy loss) with the &#948;-ray cut off energy of &#969;0 = 200 eV. We experimentally verified that REL (&#969;0 = 200 eV) gives a universal function for wide energy range in CR-39 PNTD. This work has been done as part of a basic study in the measurement of secondary short range tracks produced by target fragmentation reactions in proton cancer therapy fields.
書誌情報 Radiation Measurements

巻 50, p. 232-236, 発行日 2013-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 1350-4487
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:49:51.202152
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3