Quantitative 17O imaging towards oxygen consumption study in tumor bearing mice at 7 T

https://repo.qst.go.jp/records/46570
https://repo.qst.go.jp/records/46570
b26cfccb-26f9-4742-a6b8-50aa05000491
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-07-01
タイトル
タイトル Quantitative 17O imaging towards oxygen consumption study in tumor bearing mice at 7 T
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Narazaki, Michiko

× Narazaki, Michiko

WEKO 464174

Narazaki, Michiko

Search repository
Kanazawa, Yoko

× Kanazawa, Yoko

WEKO 464175

Kanazawa, Yoko

Search repository
Koike, Sachiko

× Koike, Sachiko

WEKO 464176

Koike, Sachiko

Search repository
Ando, Koichi

× Ando, Koichi

WEKO 464177

Ando, Koichi

Search repository
Ikehira, Hiroo

× Ikehira, Hiroo

WEKO 464178

Ikehira, Hiroo

Search repository
楢崎 美智子

× 楢崎 美智子

WEKO 464179

en 楢崎 美智子

Search repository
金沢 洋子

× 金沢 洋子

WEKO 464180

en 金沢 洋子

Search repository
小池 幸子

× 小池 幸子

WEKO 464181

en 小池 幸子

Search repository
安藤 興一

× 安藤 興一

WEKO 464182

en 安藤 興一

Search repository
池平 博夫

× 池平 博夫

WEKO 464183

en 池平 博夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 17O magnetic resonance imaging (MRI) using a conventional pulse sequence was explored as a method of quantitative imaging towards regional oxygen consumption rate measurement for tumor evaluation in mice. At 7 T, fast imaging with steady state (FISP) was the best among gradient echo, fast spin echo and FISP for the purpose. The distribution of natural abundance H2 17O in mice was visualized under spatial resolution of 2.5x2.5 mm2 by FISP in 10 min. The signal intensity by FISP showed a linear relationship with 17O quantity both in phantom and mice. Following the injection of 5% 17O enriched saline, 17O redistribution was monitored in temporal resolution down to 5 sec with an image quality sufficient to distinguish each organ. The image of labeled water produced from inhaled 17O2 gas was also obtained. The present method provides quantitative 17O images under sufficient temporal and spatial resolution for the evaluation of oxygen consumption rate in each organ. Experiments using various model compounds of ROH type clarified that the signal contribution of body constituents other than water in the present in vivo 17O FISP image was negligible.
書誌情報 Magnetic Resonance Imaging

巻 31, 号 5, p. 643-650, 発行日 2013-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 0730-725X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.mri.2012.10.009
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:50:11.307076
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3