ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Comparison of total MU and segment areas in VMAT and step-and-shoot IMRT plans

https://repo.qst.go.jp/records/46514
https://repo.qst.go.jp/records/46514
8667f35e-b646-435e-ae75-202131b84898
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-03-29
タイトル
タイトル Comparison of total MU and segment areas in VMAT and step-and-shoot IMRT plans
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kawashima, Motohiro

× Kawashima, Motohiro

WEKO 463525

Kawashima, Motohiro

Search repository
Ozawa, Shuichi

× Ozawa, Shuichi

WEKO 463526

Ozawa, Shuichi

Search repository
Haga, Akihiro

× Haga, Akihiro

WEKO 463527

Haga, Akihiro

Search repository
Sakumi, Akira

× Sakumi, Akira

WEKO 463528

Sakumi, Akira

Search repository
Kurokawa, Chie

× Kurokawa, Chie

WEKO 463529

Kurokawa, Chie

Search repository
Sugimoto, Satoru

× Sugimoto, Satoru

WEKO 463530

Sugimoto, Satoru

Search repository
Karasawa, Kumiko

× Karasawa, Kumiko

WEKO 463531

Karasawa, Kumiko

Search repository
Nakagawa, Keiichi

× Nakagawa, Keiichi

WEKO 463532

Nakagawa, Keiichi

Search repository
Sasai, Keisuke

× Sasai, Keisuke

WEKO 463533

Sasai, Keisuke

Search repository
川嶋 基敬

× 川嶋 基敬

WEKO 463534

en 川嶋 基敬

Search repository
唐澤 久美子

× 唐澤 久美子

WEKO 463535

en 唐澤 久美子

Search repository
抄録
内容記述タイプ Abstract
内容記述 We compared treatment plans for volumetric intensity-modulated arc therapy (VMAT) and step-and-shoot intensity-modulated radiation therapy (IMRT) in terms of their monitor unit (MU) and segment area at each control point to investigate the difference between the two methods. We investigated three sites: prostate (three cases), head and neck (three cases), and pleura (two cases). We used the total MU and the MU weighted average of segment area (MWSA) in each plan to compare VMAT and IMRT plans. VMAT plans tended to have a larger MWSA and a lower total MU than did IMRT plans in all sites, although there was little difference between dose indices in either irradiation technique. We conclude that VMAT is a better treatment technique due to its higher MU efficiency caused by the larger segment area.
書誌情報 Radiological Physics and Technology

巻 6, 号 1, p. 14-20, 発行日 2012-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-012-0164-3
関連サイト
識別子タイプ URI
関連識別子 http://link.springer.com/article/10.1007%2Fs12194-012-0164-3
関連名称 http://link.springer.com/article/10.1007%2Fs12194-012-0164-3
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:50:51.938255
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3