ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Measurements of 131I in the thyroids of employees involved in the Fukushima Daiichi nuclear power station accident

https://repo.qst.go.jp/records/46489
https://repo.qst.go.jp/records/46489
cc272bb5-6b0a-4313-a75a-421c62749e7e
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2013-02-13
タイトル
タイトル Measurements of 131I in the thyroids of employees involved in the Fukushima Daiichi nuclear power station accident
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kurihara, Osamu

× Kurihara, Osamu

WEKO 463237

Kurihara, Osamu

Search repository
Kanai, Katsuta

× Kanai, Katsuta

WEKO 463238

Kanai, Katsuta

Search repository
Nakagawa, Takahiro

× Nakagawa, Takahiro

WEKO 463239

Nakagawa, Takahiro

Search repository
Takada, Chie

× Takada, Chie

WEKO 463240

Takada, Chie

Search repository
Tsujimura, Norio

× Tsujimura, Norio

WEKO 463241

Tsujimura, Norio

Search repository
Momose, Takumaro

× Momose, Takumaro

WEKO 463242

Momose, Takumaro

Search repository
Furuta, Sadaaki

× Furuta, Sadaaki

WEKO 463243

Furuta, Sadaaki

Search repository
栗原 治

× 栗原 治

WEKO 463244

en 栗原 治

Search repository
抄録
内容記述タイプ Abstract
内容記述 The Great East Japan Earthquake Disaster on 11 March 2011 caused an unprecedented accident at the
Fukushima Daiichi nuclear power station operated by Tokyo Electric Power Company (TEPCO).
Nuclear Fuel Cycle Engineering Laboratories of Japan Atomic Energy Agency performed internal dose
measurements of 560 employees involved in the accident during the period from 20 April to 5 August in
2011 at the request of TEPCO. The present paper describes our measurements of 131I in the thyroid that
is the predominant contributor to the internal dose. These measurements were carried out using an
HPGe detector installed in a low-background shielded chamber made of 20-cm-thick steel and the
detector was placed adjacent to the subject's neck. The typical minimum detectable activity of this
technique was 10 Bq for a counting time of 10 min; however, this sensitivity made it difficult to identify a
residual thyroid content of 131I corresponding to a committed effective dose of 20 mSv for late subjects.
This paper discussed technical issues experienced through the measurements such as the influence of 131I
in the rest of the body, the calibration phantom of use, and so on.
書誌情報 Journal of Nuclear Science and Technology

巻 50, 号 2, p. 122-129, 発行日 2013-02
ISSN
収録物識別子タイプ ISSN
収録物識別子 0022-3131
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:51:11.802855
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3