WEKO3
アイテム
Effective Performance of T1-weighted FLAIR Imaging with BLADE in Pediatric Brains
https://repo.qst.go.jp/records/46469
https://repo.qst.go.jp/records/464690a2606a8-f881-4e6c-9716-5f70870fbe11
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-12-21 | |||||
タイトル | ||||||
タイトル | Effective Performance of T1-weighted FLAIR Imaging with BLADE in Pediatric Brains | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tachibana, Yasuhiko
× Tachibana, Yasuhiko× Niwa, Tetsu× Kusagiri, Kouki× Aida, Noriko× et.al× 立花 泰彦× 丹羽 徹× 草切 孝貴× 相田 典子 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PURPOSE: In magnetic resonance imaging of the brain, BLADE is used to compensate for head motion. The technique focuses mainly on acquisition of T(2)-weighted or contrast-enhanced T(1)-weighted images in adults; its utility for nonenhanced T(1)-weighted imaging in children is not well established. We compared the quality of T(1)-weighted fluid-attenuated inversion recovery brain imaging with BLADE (T(1)-FLAIR-BLADE) to that of conventional spin-echo T(1)-weighted imaging (T(1)-SE) in pediatric patients who cannot stay still during MR imaging. \nMATERIALS AND METHODS: Our investigation included a volunteer study and a retrospective clinical study. Six healthy adult volunteers underwent scanning to compare the contrast of T(1)-SE, T(1)-weighted fluid-attenuated inversion recovery imaging (T(1)-FLAIR), and T(1)-FLAIR-BLADE at both 1.5 and 3 tesla. Comparison was based on scores assigned independently by 2 blinded observers and by calculated contrast-to-noise ratio. The clinical study included 20 children who underwent both T(1)-SE and T(1)-FLAIR-BLADE at either 1.5 (n = 9) or 3 T (n = 11). On each sequence, 2 blinded observers independently scored visualization of the cerebral gyri and contrast between gray and white matter. We compared scores between sequences separately for 1.5 and 3T using Wilcoxon signed-rank tests. \nRESULTS: At both 1.5 and 3T, contrast was better using T(1)-FLAIR and T(1)-FLAIR-BLADE than T(1)-SE in volunteers, and overall scores were significantly higher with T(1)-FLAIR-BLADE (P < 0.05) than T(1)-SE in the clinical study. \nCONCLUSION: T(1)-FLAIR-BLADE may be superior to T(1)-SE in demonstrating brain structures in children who cannot stay still and may be used to supplement or replace T(1)-SE when T(1)-SE is insufficient for patient motion. |
|||||
書誌情報 |
Magnetic Resonance in Medical Sciences 巻 11, 号 1, p. 17-26, 発行日 2012 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-3182 |