  1. 原著論文

Effective Performance of T1-weighted FLAIR Imaging with BLADE in Pediatric Brains

https://repo.qst.go.jp/records/46469
https://repo.qst.go.jp/records/46469
0a2606a8-f881-4e6c-9716-5f70870fbe11
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-12-21
タイトル
タイトル Effective Performance of T1-weighted FLAIR Imaging with BLADE in Pediatric Brains
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tachibana, Yasuhiko

× Tachibana, Yasuhiko

WEKO 463011

Tachibana, Yasuhiko

Search repository
Niwa, Tetsu

× Niwa, Tetsu

WEKO 463012

Niwa, Tetsu

Search repository
Kusagiri, Kouki

× Kusagiri, Kouki

WEKO 463013

Kusagiri, Kouki

Search repository
Aida, Noriko

× Aida, Noriko

WEKO 463014

Aida, Noriko

Search repository
et.al

× et.al

WEKO 463015

et.al

Search repository
立花 泰彦

× 立花 泰彦

WEKO 463016

en 立花 泰彦

Search repository
丹羽 徹

× 丹羽 徹

WEKO 463017

en 丹羽 徹

Search repository
草切 孝貴

× 草切 孝貴

WEKO 463018

en 草切 孝貴

Search repository
相田 典子

× 相田 典子

WEKO 463019

en 相田 典子

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE: In magnetic resonance imaging of the brain, BLADE is used to compensate for head motion. The technique focuses mainly on acquisition of T(2)-weighted or contrast-enhanced T(1)-weighted images in adults; its utility for nonenhanced T(1)-weighted imaging in children is not well established. We compared the quality of T(1)-weighted fluid-attenuated inversion recovery brain imaging with BLADE (T(1)-FLAIR-BLADE) to that of conventional spin-echo T(1)-weighted imaging (T(1)-SE) in pediatric patients who cannot stay still during MR imaging.
\nMATERIALS AND METHODS: Our investigation included a volunteer study and a retrospective clinical study. Six healthy adult volunteers underwent scanning to compare the contrast of T(1)-SE, T(1)-weighted fluid-attenuated inversion recovery imaging (T(1)-FLAIR), and T(1)-FLAIR-BLADE at both 1.5 and 3 tesla. Comparison was based on scores assigned independently by 2 blinded observers and by calculated contrast-to-noise ratio. The clinical study included 20 children who underwent both T(1)-SE and T(1)-FLAIR-BLADE at either 1.5 (n = 9) or 3 T (n = 11). On each sequence, 2 blinded observers independently scored visualization of the cerebral gyri and contrast between gray and white matter. We compared scores between sequences separately for 1.5 and 3T using Wilcoxon signed-rank tests.
\nRESULTS: At both 1.5 and 3T, contrast was better using T(1)-FLAIR and T(1)-FLAIR-BLADE than T(1)-SE in volunteers, and overall scores were significantly higher with T(1)-FLAIR-BLADE (P < 0.05) than T(1)-SE in the clinical study.
\nCONCLUSION: T(1)-FLAIR-BLADE may be superior to T(1)-SE in demonstrating brain structures in children who cannot stay still and may be used to supplement or replace T(1)-SE when T(1)-SE is insufficient for patient motion.
書誌情報 Magnetic Resonance in Medical Sciences

巻 11, 号 1, p. 17-26, 発行日 2012
ISSN
収録物識別子タイプ ISSN
収録物識別子 1347-3182
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:51:26.520935
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3