ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Biological dosimetry by the triage dicentric chromosome assay - Further validation of international networking

https://repo.qst.go.jp/records/46430
https://repo.qst.go.jp/records/46430
45ad9445-6801-4d88-a981-9a62d8b381cf
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-11-01
タイトル
タイトル Biological dosimetry by the triage dicentric chromosome assay - Further validation of international networking
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Wilkins, Ruth

× Wilkins, Ruth

WEKO 462515

Wilkins, Ruth

Search repository
Suto, Yumiko

× Suto, Yumiko

WEKO 462516

Suto, Yumiko

Search repository
Prasanna, Pataje

× Prasanna, Pataje

WEKO 462517

Prasanna, Pataje

Search repository
et.al

× et.al

WEKO 462518

et.al

Search repository
數藤 由美子

× 數藤 由美子

WEKO 462519

en 數藤 由美子

Search repository
抄録
内容記述タイプ Abstract
内容記述 Biological dosimetry is an essential tool for estimating radiation doses received to personnel when physical dosimetry is not available or inadequate. The current preferred biodosimetry method is based on the measurement of radiation-specific dicentric chromosomes in exposed individuals' peripheral blood lymphocytes. However, this method is labor-, time- and expertise-demanding. Consequently, for
mass casualty applications, strategies have been developed to increase its throughput. One such strategy is to develop validated cytogenetic biodosimetry laboratory networks, both national and international. In a previous study, the dicentric chromosome assay (DCA) was validated in our cytogenetic biodosimetry
network involving five geographically dispersed laboratories. A complementary strategy to further enhance the throughput of the DCA among inter-laboratory networks is to use a triage DCA where dose assessments are made by truncating the labor-demanding and time-consuming metaphase spread analysis to 20-50 metaphase spreads instead of routine 500-1000 metaphase spread analysis. Our laboratory network also validated this triage DCA, however, these dose estimates were made using calibration curves generated in each laboratory from the blood samples irradiated in a single laboratory.
In an emergency situation, dose estimates made using pre-existing calibration curves which may vary according to radiation type and dose rate and therefore influence the assessed dose. Here, we analyze the effect of using a pre-existing calibration curve on assessed dose among our network laboratories. The dose estimates were made by analyzing 1000 metaphase spreads as well as triage quality scoring and compared to actual physical doses applied to the samples for validation. The dose estimates in the laboratory partners were in good agreement with the applied physical doses and determined to be adequate for guidance in the treatment of acute radiation syndrome.
書誌情報 Radiation Measurements

巻 46, 号 9, p. 923-928, 発行日 2011-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 1350-4487
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:51:54.141722
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3