ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Fluence-to-dose conversion coefficients for aircrew dosimetry based on the new ICRP recommendations

https://repo.qst.go.jp/records/46421
https://repo.qst.go.jp/records/46421
583b9d5a-4190-455c-9aa9-4f6c09a5aee2
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-10-11
タイトル
タイトル Fluence-to-dose conversion coefficients for aircrew dosimetry based on the new ICRP recommendations
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sato, Tatsuhiko

× Sato, Tatsuhiko

WEKO 462430

Sato, Tatsuhiko

Search repository
Endo, Akira

× Endo, Akira

WEKO 462431

Endo, Akira

Search repository
Yasuda, Hiroshi

× Yasuda, Hiroshi

WEKO 462432

Yasuda, Hiroshi

Search repository
Niita, Koji

× Niita, Koji

WEKO 462433

Niita, Koji

Search repository
et.al

× et.al

WEKO 462434

et.al

Search repository
保田 浩志

× 保田 浩志

WEKO 462435

en 保田 浩志

Search repository
抄録
内容記述タイプ Abstract
内容記述 The estimation of the fluence-to-effective dose conversion coefficients used especially for aircrew dosimetry is an important issue, since the geometrical conditions of aircrew exposure are considered not to be represented by the standard irradiation geometries such as the anterior-to-posterior (AP) and isotropic (ISO) geometries. We therefore calculated the dose conversion coefficients for neutrons and protons based on the ICRP 2007 Recommendations for three additional irradiation geometries: semi-isotropic irradiation from the upper hemisphere, and geometries closely representing the geometrical situations of aircrew exposure for two different flight conditions. The calculation was performed by the PHITS code coupled with the ICRP/ICRU adult reference computational phantoms. It was found from the calculation that (1) the conversion coefficients for the irradiation geometries closely representing the geometrical situations of aircrew exposure agree better with the corresponding data for the isotropic irradiation than those for the semi-isotropic irradiation; (2) the error associated with the assumption of the isotropic irradiation in the aircrew dosimetry is less than only 1% for conventional flight conditions. These findings indicate the adequacy of the use of dose conversion coefficients for the isotropic irradiation geometry in aircrew dosimetry.
書誌情報 Progress in Nuclear Science and Technology

巻 1, p. 134-137, 発行日 2011-02
ISSN
収録物識別子タイプ ISSN
収録物識別子 2185-4823
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:52:01.740278
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3