{"_buckets": {"deposit": "d6a17e3f-1777-4d25-9448-8b7b91c434a4"}, "_deposit": {"created_by": 1, "id": "46402", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46402"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046402", "sets": ["1"]}, "author_link": ["462245", "462237", "462232", "462235", "462233", "462246", "462234", "462228", "462236", "462243", "462242", "462230", "462241", "462239", "462229", "462238", "462231", "462244", "462240"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "324", "bibliographicPageStart": "319", "bibliographicVolumeNumber": "49", "bibliographic_titles": [{"bibliographic_title": "Cosmic Research"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The dose reduction rates brought about by the installation of additional water shielding in a space craft are calculated in the paper using the particles and heavy ion transport code system PHITS, which can deal with transport of all kinds of hadrons and heavy ions with energies up to 100 GeV/n in three dimensional\nphase spaces. In the PHITS simulation, an imaginary spacecraft was irradiated isotropically by cosmic rays with charges up to 28 and energies up to 100 GeV/n, and the dose reduction rates due to water shielding were evaluated for 5 types of doses: the dose equivalents obtained from the LET and linear energy spectra, the dose equivalents to skin and red bone marrow, and the effective dose equivalent. The results of the simulation indi cate that the dose reduction rates differ according to the type of dose evaluated. For example, 5 g/cm2 water shielding reduces the effective dose equivalent and the LET dose equivalent by approximately 14% and 32%, respectively. Such degrees of dose reduction can be regarded to make water shielding worth the efforts required to install it.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0010-9525", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sato, Tatsuhiko"}], "nameIdentifiers": [{"nameIdentifier": "462228", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Niita, Kohji"}], "nameIdentifiers": [{"nameIdentifier": "462229", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shurshakov, V.A."}], "nameIdentifiers": [{"nameIdentifier": "462230", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yarmanova, E.N."}], "nameIdentifiers": [{"nameIdentifier": "462231", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nikolaev, I.V."}], "nameIdentifiers": [{"nameIdentifier": "462232", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwase, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "462233", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sihver, L."}], "nameIdentifiers": [{"nameIdentifier": "462234", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mancusi, D."}], "nameIdentifiers": [{"nameIdentifier": "462235", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Endo, Akira"}], "nameIdentifiers": [{"nameIdentifier": "462236", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuda, Norihiro"}], "nameIdentifiers": [{"nameIdentifier": "462237", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwamoto, Yosuke"}], "nameIdentifiers": [{"nameIdentifier": "462238", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakashima, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "462239", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakamoto, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "462240", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "462241", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takada, Masashi"}], "nameIdentifiers": [{"nameIdentifier": "462242", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamura, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "462243", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "保田 浩志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "462244", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高田 真志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "462245", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村 尚司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "462246", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Evaluation of Dose Rate Reduction in a Spacecraft Compartment due to Additional Water Shield", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Evaluation of Dose Rate Reduction in a Spacecraft Compartment due to Additional Water Shield"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46402", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-10-01"}, "publish_date": "2012-10-01", "publish_status": "0", "recid": "46402", "relation": {}, "relation_version_is_last": true, "title": ["Evaluation of Dose Rate Reduction in a Spacecraft Compartment due to Additional Water Shield"], "weko_shared_id": -1}
Evaluation of Dose Rate Reduction in a Spacecraft Compartment due to Additional Water Shield
https://repo.qst.go.jp/records/46402
https://repo.qst.go.jp/records/464023a85efa9-4f69-4e98-8c7b-a154b69f1a79
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-10-01 | |||||
タイトル | ||||||
タイトル | Evaluation of Dose Rate Reduction in a Spacecraft Compartment due to Additional Water Shield | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Sato, Tatsuhiko
× Sato, Tatsuhiko× Niita, Kohji× Shurshakov, V.A.× Yarmanova, E.N.× Nikolaev, I.V.× Iwase, Hiroshi× Sihver, L.× Mancusi, D.× Endo, Akira× Matsuda, Norihiro× Iwamoto, Yosuke× Nakashima, Hiroshi× Sakamoto, Yukio× Yasuda, Hiroshi× Takada, Masashi× Nakamura, Takashi× 保田 浩志× 高田 真志× 中村 尚司 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The dose reduction rates brought about by the installation of additional water shielding in a space craft are calculated in the paper using the particles and heavy ion transport code system PHITS, which can deal with transport of all kinds of hadrons and heavy ions with energies up to 100 GeV/n in three dimensional phase spaces. In the PHITS simulation, an imaginary spacecraft was irradiated isotropically by cosmic rays with charges up to 28 and energies up to 100 GeV/n, and the dose reduction rates due to water shielding were evaluated for 5 types of doses: the dose equivalents obtained from the LET and linear energy spectra, the dose equivalents to skin and red bone marrow, and the effective dose equivalent. The results of the simulation indi cate that the dose reduction rates differ according to the type of dose evaluated. For example, 5 g/cm2 water shielding reduces the effective dose equivalent and the LET dose equivalent by approximately 14% and 32%, respectively. Such degrees of dose reduction can be regarded to make water shielding worth the efforts required to install it. |
|||||
書誌情報 |
Cosmic Research 巻 49, 号 4, p. 319-324, 発行日 2011-08 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0010-9525 |