A single-ring OpenPET enabling PET imaging during radiotherapy
https://repo.qst.go.jp/records/46367
https://repo.qst.go.jp/records/46367a66d12f9-128d-4692-a965-fc53b337fb9b
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-07-30 | |||||
タイトル | ||||||
タイトル | A single-ring OpenPET enabling PET imaging during radiotherapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tashima, Hideaki
× Tashima, Hideaki× Yamaya, Taiga× Yoshida, Eiji× Kinouchi, Shoko× Watanabe, Mitsuo× Tanaka, Eiichi× 田島 英朗× 山谷 泰賀× 吉田 英治× 木内 尚子× 田中 榮一 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We develop an OpenPET system which can provide an accessible open space to the patient during PET scanning. Our first-generation OpenPET geometry which we called dual-ring OpenPET consisted of two separated detector rings and it could extend its axial field of view (FOV) therefore enabling imaging the gap region in addition to the in-ring region. However, applications such as dose verification by in-beam PET measurement during particle therapy and real-time tumor tracking by PET require sensitivity focused onto the gap rather than on the wide FOV. In this paper, we propose a second-generation OpenPET geometry, single-ring OpenPET, which can provide an accessible and observable open space with higher sensitivity and a reduced number of detectors than the earlier one. The proposed geometry has a cylinder shape cut at a slant angle, in which the shape of each cut end becomes an ellipse. We provided a theoretical analysis for sensitivity of the proposed geometry, compared with the dual-ring OpenPET and a geometry where the conventional PET was positioned at a slant angle against the patient bed to form an accessible open space, which we called a slant PET. The central sensitivity depends on the solid angle of these geometries. As a result, we found that the single-ring OpenPET has a sensitivity 1.2 times higher than the dual-ring OpenPET and 1.3 times higher than the slant PET when designed for a 600 mm bed width with 300 mm accessible open space and about 200 detector blocks, each with a front area of 2500 mm2. In addition, numerical simulation was carried out to show the imaging property of the proposed geometry realized with the ellipsoidal rings and these results indicate that the depth-of-interaction detector can provide uniform resolution even when the detectors are arranged in an ellipsoidal ring. | |||||
書誌情報 |
Physics in Medicine and Biology 巻 57, 号 14, p. 4705-4718, 発行日 2012-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-9155 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/0031-9155/57/14/4705 |