Development of Digital Reconstructed Radiography Software at New Treatment Facility for Carbon-ion Beam Scanning of National Institute of Radiological Sciences

https://repo.qst.go.jp/records/46366
https://repo.qst.go.jp/records/46366
55e32ebf-5cc8-4403-bc63-9152cb77f0b5
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-07-26
タイトル
タイトル Development of Digital Reconstructed Radiography Software at New Treatment Facility for Carbon-ion Beam Scanning of National Institute of Radiological Sciences
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mori, Shinichiro

× Mori, Shinichiro

WEKO 461860

Mori, Shinichiro

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 461861

Inaniwa, Taku

Search repository
Kuwae, Tsunekazu

× Kuwae, Tsunekazu

WEKO 461862

Kuwae, Tsunekazu

Search repository
Matsuzaki, Yuka

× Matsuzaki, Yuka

WEKO 461863

Matsuzaki, Yuka

Search repository
Kumagai, Motoki

× Kumagai, Motoki

WEKO 461864

Kumagai, Motoki

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 461865

Furukawa, Takuji

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 461866

Shirai, Toshiyuki

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 461867

Noda, Kouji

Search repository
森 慎一郎

× 森 慎一郎

WEKO 461868

en 森 慎一郎

Search repository
稲庭 拓

× 稲庭 拓

WEKO 461869

en 稲庭 拓

Search repository
桑江 常和

× 桑江 常和

WEKO 461870

en 桑江 常和

Search repository
松崎 有華

× 松崎 有華

WEKO 461871

en 松崎 有華

Search repository
熊谷 始紀

× 熊谷 始紀

WEKO 461872

en 熊谷 始紀

Search repository
古川 卓司

× 古川 卓司

WEKO 461873

en 古川 卓司

Search repository
白井 敏之

× 白井 敏之

WEKO 461874

en 白井 敏之

Search repository
野田 耕司

× 野田 耕司

WEKO 461875

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 To increase the accuracy of carbon ion beam scanning therapy, we have developed a GUI (graphical user interface)-based digitally-reconstructed radiograph (DRR) software system for use in routine clinical practice at our center. The DRR software is used in particular scenarios in the new treatment facility to achieve the same level of geometrical accuracy at the treatment as at the imaging session. DRR calculation is implemented simply as the summation of CT image voxel values along the x-ray projection ray. Since we implemented GPU (graphics processing unit)-based computation, the DRR images are calculated with a speed sufficient for the particular clinical practice requirements. Since high spatial resolution flat panel detector (FPD) images should be registered to the reference DRR images in patient setup process in any scenarios, the DRR images also needs higher spatial resolution close to that of FPD images. To overcome the limitation of the CT spatial resolution imposed by the CT voxel size, we applied image processing to improve the calculated DRR spatial resolution. The DRR software introduced here enabled patient positioning with sufficient accuracy for the implementation of carbon-ion beam scanning therapy at our center.
書誌情報 Australasian Physical & Engineering Sciences in Medicine

巻 35, 号 2, p. 221-229, 発行日 2012-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 0158-9938
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:52:41.853366
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3