ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Clinical value of FDG-PET for preoperative evaluation of endometrial cancer

https://repo.qst.go.jp/records/46344
https://repo.qst.go.jp/records/46344
db2e41a5-fc76-4253-8f34-61a5693149cf
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-06-08
タイトル
タイトル Clinical value of FDG-PET for preoperative evaluation of endometrial cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Suga, Tsuyoshi

× Suga, Tsuyoshi

WEKO 461679

Suga, Tsuyoshi

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 461680

Saga, Tsuneo

Search repository
Nakamoto, Yuji

× Nakamoto, Yuji

WEKO 461681

Nakamoto, Yuji

Search repository
Higashi, Tatsuya

× Higashi, Tatsuya

WEKO 461682

Higashi, Tatsuya

Search repository
Hamanaka, Yasuyo

× Hamanaka, Yasuyo

WEKO 461683

Hamanaka, Yasuyo

Search repository
Hara, Tadashi

× Hara, Tadashi

WEKO 461684

Hara, Tadashi

Search repository
Fujii, Shingo

× Fujii, Shingo

WEKO 461685

Fujii, Shingo

Search repository
Togashi, Kaori

× Togashi, Kaori

WEKO 461686

Togashi, Kaori

Search repository
et.al

× et.al

WEKO 461687

et.al

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 461688

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective
Whole body positron emission tomography (PET) with F-18 fluorodeoxyglucose (FDG) has been widely used in various malignancies, but the clinical value of FDG-PET for endometrial cancer has not been fully investigated. The purpose of this study was to evaluate the usefulness of FDG-PET for preoperative evaluation of endometrial cancer.
Methods
Forty female patients suspected of having endometrial cancer were included in this study. All patients underwent an FDG-PET or PET/CT scan, and images were interpreted visually. The diagnostic performance in detecting the primary tumor, regional nodal status, and distant metastasis was determined. In addition, the usefulness of PET was assessed in terms of additional information and clinical impact for therapeutic management.
Results
Of 40 patients, 30 were histologically confirmed to have endometrial cancer. The patient-based sensitivity and specificity of FDG-PET for primary tumors were 83 and 100%, respectively, and 100 and 100%, respectively, for nodal metastases. There were 12 distant metastases in 6 patients and two second primary cancers in two patients, which were all accurately diagnosed by PET on a patient-basis. PET yielded 12 additional findings in 10 patients, and had a bearing on the therapeutic management of four patients, including one patient with recurrent breast cancer.
Conclusions
FDG-PET had a reasonably high diagnostic accuracy in endometrial cancer. Although the number of cases with clinical impact was limited, additional information by PET was obtained in one-third of the cases.
書誌情報 Annals of Nuclear Medicine

巻 25, 号 4, p. 269-275, 発行日 2011-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
DOI
識別子タイプ DOI
関連識別子 10.1007/s12149-011-0474-2
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:52:57.382197
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3