ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Acceleration of heavy ions with a new RF system at HIMAC synchrotron

https://repo.qst.go.jp/records/46302
https://repo.qst.go.jp/records/46302
767a0f7a-6751-4211-9961-1409100a3c10
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-04-20
タイトル
タイトル Acceleration of heavy ions with a new RF system at HIMAC synchrotron
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Fujimoto, Tetsuya

× Fujimoto, Tetsuya

WEKO 461270

Fujimoto, Tetsuya

Search repository
Kanazawa, Mitsutaka

× Kanazawa, Mitsutaka

WEKO 461271

Kanazawa, Mitsutaka

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 461272

Shirai, Toshiyuki

Search repository
Iwata, Yoshiyuki

× Iwata, Yoshiyuki

WEKO 461273

Iwata, Yoshiyuki

Search repository
Uchiyama, Hiroshi

× Uchiyama, Hiroshi

WEKO 461274

Uchiyama, Hiroshi

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 461275

Noda, Kouji

Search repository
金澤 光隆

× 金澤 光隆

WEKO 461276

en 金澤 光隆

Search repository
白井 敏之

× 白井 敏之

WEKO 461277

en 白井 敏之

Search repository
岩田 佳之

× 岩田 佳之

WEKO 461278

en 岩田 佳之

Search repository
野田 耕司

× 野田 耕司

WEKO 461279

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 A fast three-dimensional scanning irradiation method is under development at the Heavy Ion Medical Accelerator in Chiba (HIMAC) as the next stage of heavy ion cancer therapy. This method requires highly accurate control of the beam size, energy, and intensity. To improve the accelerated beam's quality, a new scheme for the synchrotron RF system has been developed. The new system adopts a periodic time clock system (T-clock) instead of an ordinary B-clock system. The new T-clock system is synchronized with a power line frequency of 50 Hz for synchronization with the synchrotron power supply. An ordinary Bclock system results in error pulses owing to the small analog signal of the magnetic field of the main dipole magnet, and the errors cause dipole oscillation of the beam in the RF bucket. Using the new T-clock generator at 192 kHz, we have observed an improvement in the acceleration efficiency and bunch shape compared to the B-clock generator.
書誌情報 Nuclear Instruments & Methods in Physics Research Section B

巻 269, 号 24, p. 2886-2890, 発行日 2011-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-583X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nimb.2011.04.029
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:53:28.117071
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3