  1. 原著論文

A fluorescent screen + CCD system for quality assurance of therapeutic scanned ion beams

https://repo.qst.go.jp/records/46301
https://repo.qst.go.jp/records/46301
496053e0-0134-4228-92fc-d04bce3cac17
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-04-20
タイトル
タイトル A fluorescent screen + CCD system for quality assurance of therapeutic scanned ion beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takeshita, Eri

× Takeshita, Eri

WEKO 461256

Takeshita, Eri

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 461257

Furukawa, Takuji

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 461258

Inaniwa, Taku

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 461259

Satou, Shinji

Search repository
Himukai, Takeshi

× Himukai, Takeshi

WEKO 461260

Himukai, Takeshi

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 461261

Shirai, Toshiyuki

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 461262

Noda, Kouji

Search repository
竹下 英里

× 竹下 英里

WEKO 461263

en 竹下 英里

Search repository
古川 卓司

× 古川 卓司

WEKO 461264

en 古川 卓司

Search repository
稲庭 拓

× 稲庭 拓

WEKO 461265

en 稲庭 拓

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 461266

en 佐藤 眞二

Search repository
日向 猛

× 日向 猛

WEKO 461267

en 日向 猛

Search repository
白井 敏之

× 白井 敏之

WEKO 461268

en 白井 敏之

Search repository
野田 耕司

× 野田 耕司

WEKO 461269

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 A fluorescent screen + a charge coupled device (CCD) system were developed to verify the performance of scanned ion beams at the HIMAC. The fluorescent light from the screen is observed by the CCD camera. Two-dimensional fields, produced by the scanning process, i.e., the position and the size of the beam for each scan, represent of the important issues in scanning irradiation. In the developed system, the twodimensional relative fluence and the flatness of the irradiation field were measured in a straightforward technique from the luminance distribution on the screen. The position and the size of the beams were obtained from centroid computation results of the brightness. By the good sensitivity and spatial resolution of the fluorescent screen + CCD system, the scanned ion beams were verified as the measurements at the HIMAC prototype scanning system.
書誌情報 Nuclear Instruments & Methods in Physics Research Section B

巻 269, 号 24, p. 2936-2940, 発行日 2011-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-583X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nimb.2011.04.043
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:53:28.792515
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3