ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Beam stability improvement of the HIMAC synchrotron using a feed-forward system for magnet power supplies

https://repo.qst.go.jp/records/46298
https://repo.qst.go.jp/records/46298
4c6d56d6-280a-4912-8e27-589470787dcf
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-04-20
タイトル
タイトル Beam stability improvement of the HIMAC synchrotron using a feed-forward system for magnet power supplies
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Katagiri, Ken

× Katagiri, Ken

WEKO 461206

Katagiri, Ken

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 461207

Furukawa, Takuji

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 461208

Mizushima, Kota

Search repository
Uchiyama, Hiroshi

× Uchiyama, Hiroshi

WEKO 461209

Uchiyama, Hiroshi

Search repository
Takeshita, Eri

× Takeshita, Eri

WEKO 461210

Takeshita, Eri

Search repository
Himukai, Takeshi

× Himukai, Takeshi

WEKO 461211

Himukai, Takeshi

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 461212

Satou, Shinji

Search repository
Iwata, Yoshiyuki

× Iwata, Yoshiyuki

WEKO 461213

Iwata, Yoshiyuki

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 461214

Shirai, Toshiyuki

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 461215

Noda, Kouji

Search repository
片桐 健

× 片桐 健

WEKO 461216

en 片桐 健

Search repository
古川 卓司

× 古川 卓司

WEKO 461217

en 古川 卓司

Search repository
水島 康太

× 水島 康太

WEKO 461218

en 水島 康太

Search repository
竹下 英里

× 竹下 英里

WEKO 461219

en 竹下 英里

Search repository
日向 猛

× 日向 猛

WEKO 461220

en 日向 猛

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 461221

en 佐藤 眞二

Search repository
岩田 佳之

× 岩田 佳之

WEKO 461222

en 岩田 佳之

Search repository
白井 敏之

× 白井 敏之

WEKO 461223

en 白井 敏之

Search repository
野田 耕司

× 野田 耕司

WEKO 461224

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to realize a precise dose distribution in heavy-ion cancer therapy, high beam stability is required for the accelerator complex. Owing to load fluctuation caused by the upper ring, which is one of the two rings in HIMAC, current dips of 5-10 Hz were observed in the power supply for the bending/quadrupole magnet of the other lower ring. The parameters of the beam stability, such as the spill variation, the beam position, and the size, were adversely affected by the current dips. In order to suppress these current dips, we developed a new feed-forward system in the magnet power supply. We verified the performance of the feed-forward system by measuring the suppression of the current dips. We also performed beam
experiments to measure the variation of the horizontal tune and the structure of the beam spill, which is slowly extracted by the resonance method. The experimental result showed that the current dips were successfully reduced by the system to DI/I =1E-6. It was also confirmed that the horizontal tune and the spill structure could be stabilized by the current dip suppression.
書誌情報 Nuclear Instruments & Methods in Physics Research Section B

巻 269, 号 24, p. 2905-2910, 発行日 2011-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-583X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nimb.2011.04.030
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:53:31.197146
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3