ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Moving target irradiation with fast rescanning and gating in particle therapy

https://repo.qst.go.jp/records/46270
https://repo.qst.go.jp/records/46270
5ba9f360-4f3d-45d2-9a97-ede3c868a53b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-02-23
タイトル
タイトル Moving target irradiation with fast rescanning and gating in particle therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furukawa, Takuji

× Furukawa, Takuji

WEKO 460821

Furukawa, Takuji

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 460822

Inaniwa, Taku

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 460823

Satou, Shinji

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 460824

Shirai, Toshiyuki

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 460825

Mori, Shinichiro

Search repository
Takeshita, Eri

× Takeshita, Eri

WEKO 460826

Takeshita, Eri

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 460827

Mizushima, Kota

Search repository
Himukai, Takeshi

× Himukai, Takeshi

WEKO 460828

Himukai, Takeshi

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 460829

Noda, Kouji

Search repository
古川 卓司

× 古川 卓司

WEKO 460830

en 古川 卓司

Search repository
稲庭 拓

× 稲庭 拓

WEKO 460831

en 稲庭 拓

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 460832

en 佐藤 眞二

Search repository
白井 敏之

× 白井 敏之

WEKO 460833

en 白井 敏之

Search repository
森 慎一郎

× 森 慎一郎

WEKO 460834

en 森 慎一郎

Search repository
竹下 英里

× 竹下 英里

WEKO 460835

en 竹下 英里

Search repository
水島 康太

× 水島 康太

WEKO 460836

en 水島 康太

Search repository
日向 猛

× 日向 猛

WEKO 460837

en 日向 猛

Search repository
野田 耕司

× 野田 耕司

WEKO 460838

en 野田 耕司

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: In moving target irradiation with pencil beam scanning, the interplay effect between the target motion and the scanned beam is a problem because this effect causes over or under dosage in the target volume. To overcome this, we have studied rescanning using a gating technique.
Methods: A simulation and experimental study was carried out. In the experiment, we used the fast scanning system developed at the HIMAC to verify the validity of phase controlled rescanning method, in which the time for rescanning irradiation of each slice is matched to the gating duration.
Results: Simulation and experimental results showed that controlling the scan speed to match the respiration cycle with rescans can deliver the blurred dose distribution. In the comparison between the static measurements and the moving measurements with the phase controlled rescanning method, the dose difference was less than 2% for pinpoint chambers in the target volume.
Conclusions: The simulation and experimental results demonstrated that the phase controlled rescanning method makes it possible to deliver the dose distribution close to the expected one. As an experimental result for 3D irradiation, it was estimated that blurring by the probability density function was not only for a lateral distribution, but also for a distal distribution, even in the lateral rescanning
書誌情報 Medical Physics

巻 37, 号 9, p. 4874-4879, 発行日 2010-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-2405
DOI
識別子タイプ DOI
関連識別子 10.1118/1.3481512
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:53:51.875958
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3