  1. 原著論文

A short-scan method for k(3) estimation with moderately reversible PET ligands: Application of irreversible model to early-phase PET data.

https://repo.qst.go.jp/records/46267
https://repo.qst.go.jp/records/46267
bc7f22bf-3df9-4b52-9a7d-18ca6328465f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-02-22
タイトル
タイトル A short-scan method for k(3) estimation with moderately reversible PET ligands: Application of irreversible model to early-phase PET data.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sato, Koichi

× Sato, Koichi

WEKO 460786

Sato, Koichi

Search repository
Fukushi, Kiyoshi

× Fukushi, Kiyoshi

WEKO 460787

Fukushi, Kiyoshi

Search repository
Shinoto, Hitoshi

× Shinoto, Hitoshi

WEKO 460788

Shinoto, Hitoshi

Search repository
Shimada, Hitoshi

× Shimada, Hitoshi

WEKO 460789

Shimada, Hitoshi

Search repository
Tanaka, Noriko

× Tanaka, Noriko

WEKO 460790

Tanaka, Noriko

Search repository
Hirano, Shigeki

× Hirano, Shigeki

WEKO 460791

Hirano, Shigeki

Search repository
Irie, Toshiaki

× Irie, Toshiaki

WEKO 460792

Irie, Toshiaki

Search repository
佐藤 康一

× 佐藤 康一

WEKO 460793

en 佐藤 康一

Search repository
福士 清

× 福士 清

WEKO 460794

en 福士 清

Search repository
篠遠 仁

× 篠遠 仁

WEKO 460795

en 篠遠 仁

Search repository
島田 斉

× 島田 斉

WEKO 460796

en 島田 斉

Search repository
田中 典子

× 田中 典子

WEKO 460797

en 田中 典子

Search repository
平野 成樹

× 平野 成樹

WEKO 460798

en 平野 成樹

Search repository
入江 俊章

× 入江 俊章

WEKO 460799

en 入江 俊章

Search repository
抄録
内容記述タイプ Abstract
内容記述 Long dynamic scans (60-120min) are often required for estimating the k(3) value, an index of receptor density, by positron emission tomography (PET). However, the precision of k(3) is usually low in kinetic analyses for reversible PET ligands compared with irreversible ligands. That is largely due to unstable estimation of the dissociation rate constant, k(4). We propose a novel '3P+' method for estimating k(3) of moderately reversible ligands, where a 3-parameter model without k(4) is applied to early-phase PET data to obtain a good model-fit of k(3) estimation. By using [(11)C] Pittsburgh compound B (PIB) (k(4)=0.018/min) as an example of a moderately reversible ligand, the 3P+ method simulation with a 28min PET scan yielded less than 3% k(3) relative bias with a +100% k(3) change. In [(11)C]PIB PET scans of 15 normal controls (NC) and nine patients with Alzheimer's disease (AD), the 3P+ method provided a precise k(3) estimate (mean SE of 13.6% in parietal cortex; covariance matrix method). The results revealed linear correlations (r=0.964) of parietal k(3) values in 24 subjects between 28minute 3P+ method and conventional 90minute 4-parameter method. A good separation of k(3) between NC and AD groups (P<0.001; t-test) was replicated in 28minute 3P+ method. The short-scan 3P+ method may be a practical alternative method for analyzing reversible ligands.
書誌情報 NeuroImage

巻 59, 号 4, p. 3149-3158, 発行日 2011-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 1053-8119
関連サイト
識別子タイプ URI
関連識別子 http://www.ncbi.nlm.nih.gov/pubmed/22079452
関連名称 http://www.ncbi.nlm.nih.gov/pubmed/22079452
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:53:54.175761
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3