  1. 原著論文

High-dose-rate Interstitial Brachytherapy with Computed Tomography-based Treatment Planning for Patients with Locally Advanced Uterine Cervical Carcinoma

https://repo.qst.go.jp/records/46261
https://repo.qst.go.jp/records/46261
294da571-c1ee-42ea-88d5-51a8824e8b8f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-02-06
タイトル
タイトル High-dose-rate Interstitial Brachytherapy with Computed Tomography-based Treatment Planning for Patients with Locally Advanced Uterine Cervical Carcinoma
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Saito, Junichi

× Saito, Junichi

WEKO 460713

Saito, Junichi

Search repository
Ohno, Tatsuya

× Ohno, Tatsuya

WEKO 460714

Ohno, Tatsuya

Search repository
Sakurai, Hideyuki

× Sakurai, Hideyuki

WEKO 460715

Sakurai, Hideyuki

Search repository
Kato, Hiroyuki

× Kato, Hiroyuki

WEKO 460716

Kato, Hiroyuki

Search repository
Wakatuki, Masaru

× Wakatuki, Masaru

WEKO 460717

Wakatuki, Masaru

Search repository
Noda, Shinei

× Noda, Shinei

WEKO 460718

Noda, Shinei

Search repository
Suzuki, Yoshiyuki

× Suzuki, Yoshiyuki

WEKO 460719

Suzuki, Yoshiyuki

Search repository
Shibuya, Kei

× Shibuya, Kei

WEKO 460720

Shibuya, Kei

Search repository
Takahashi, Takeo

× Takahashi, Takeo

WEKO 460721

Takahashi, Takeo

Search repository
Nakano, Takashi

× Nakano, Takashi

WEKO 460722

Nakano, Takashi

Search repository
加藤 弘之

× 加藤 弘之

WEKO 460723

en 加藤 弘之

Search repository
若月 優

× 若月 優

WEKO 460724

en 若月 優

Search repository
高橋 健夫

× 高橋 健夫

WEKO 460725

en 高橋 健夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 The aims of this study were to carry out a dose volume analysis of high-dose-rate interstitial brachytherapy with computed tomography-based treatment planning and to investigate the treatment outcome of patients with locally advanced bulky and/or irregularly shaped uterine cervical carcinoma. Between July 2003 and December 2007, 15 patients were treated with external beam radiation therapy and high-dose-rate interstitial brachytherapy with or without intracavitary brachytherapy. Seven patients were treated with interstitial brachytherapy alone, and 8 were treated with combined use of intracavitary and interstitial brachytherapy. A comparison of the volume and dose parameters with intracavitary and interstitial brachytherapy in patients who received both treatments showed that the median D90 of the high-risk clinical target volume per fraction was 4.4 Gy with intracavitary brachytherapy and 5.6 Gy with interstitial brachytherapy, and the median V100 was 66% with intracavitary brachytherapy and 85% with interstitial brachytherapy. The median D2cc of the bladder with intracavitary and interstitial brachytherapy per fraction was 5.5 Gy and 4.7 Gy, respectively, and the median D2cc of the rectum with intracavitary and interstitial brachytherapy was 5.9 Gy and 4.1 Gy, respectively. The median follow-up time was 37 months, and the overall and progression-free survival rates for all patients at 3 years were 78% and 51%, respectively. The actuarial 2-year and 3-year locoregional control rates were 80% and 71%, respectively. Dose distribution was improved with image-based interstitial brachytherapy, and satisfactory local control was achieved for patients with locally advanced uterine cervical carcinoma in which intracavitary brachytherapy may result in a suboptimal dose distribution.
書誌情報 Journal of Radiation Research

巻 52, 号 4, p. 490-495, 発行日 2011-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
DOI
識別子タイプ DOI
関連識別子 10.1269/jrr.10189
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:53:58.524312
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3