  1. 原著論文

Improvement of charge resolution for high Z/b particles in CR-39 nuclear track detectors by means of two-step etching technique

https://repo.qst.go.jp/records/46254
https://repo.qst.go.jp/records/46254
e6489d3f-45db-4c6d-89dd-5bc84616bbd7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-01-17
タイトル
タイトル Improvement of charge resolution for high Z/b particles in CR-39 nuclear track detectors by means of two-step etching technique
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 460619

Kodaira, Satoshi

Search repository
Naka, Shuichiro

× Naka, Shuichiro

WEKO 460620

Naka, Shuichiro

Search repository
Yasuda, Nakahiro

× Yasuda, Nakahiro

WEKO 460621

Yasuda, Nakahiro

Search repository
Kawashima, Hajime

× Kawashima, Hajime

WEKO 460622

Kawashima, Hajime

Search repository
Kurano, Mieko

× Kurano, Mieko

WEKO 460623

Kurano, Mieko

Search repository
Ota, Syuya

× Ota, Syuya

WEKO 460624

Ota, Syuya

Search repository
Ideguchi, Yusuke

× Ideguchi, Yusuke

WEKO 460625

Ideguchi, Yusuke

Search repository
Hasebe, Nobuyuki

× Hasebe, Nobuyuki

WEKO 460626

Hasebe, Nobuyuki

Search repository
Ogura, Kouichi

× Ogura, Kouichi

WEKO 460627

Ogura, Kouichi

Search repository
小平 聡

× 小平 聡

WEKO 460628

en 小平 聡

Search repository
仲 秀一郎

× 仲 秀一郎

WEKO 460629

en 仲 秀一郎

Search repository
安田 仲宏

× 安田 仲宏

WEKO 460630

en 安田 仲宏

Search repository
川嶋 元

× 川嶋 元

WEKO 460631

en 川嶋 元

Search repository
蔵野 美恵子

× 蔵野 美恵子

WEKO 460632

en 蔵野 美恵子

Search repository
太田 周也

× 太田 周也

WEKO 460633

en 太田 周也

Search repository
井手口 悠介

× 井手口 悠介

WEKO 460634

en 井手口 悠介

Search repository
抄録
内容記述タイプ Abstract
内容記述 We verified that the two-step etching method of the combination of pre-etching with PEW (Potassium hydroxide + Ethanol + Water) solution and post-etching with NaOH solution makes drastic improvement of charge resolution for high Z/b particles (Z: nuclear charge, b: velocity) in CR-39 nuclear track detectors. Detectors were exposed to several heavy ions from Ne to Kr with the energies of <500 MeV/n at HIMAC
(Heavy Ion Medical Accelerator in Chiba). The optimum etching conditions were determined to be a preetching of PEW solution with concentration of 60 wt% of ethanol for 40 min and a post-etching of 7N NaOH for 12 h. This resulted in a charge resolution for Kr (Z/b~60) of 0.18 c.u. (charge units). The Z/b detection threshold was increased as a function of ethanol concentration in PEW pre-etching solutions. We found that the two-step etching method would be useful technique for the precise charge identification by a single track measurement. The 60 wt% ethanol concentration in PEW would be adequate selection for the purpose of trans-iron nuclei measurement discriminating abundant light nuclei in galactic cosmic rays.
書誌情報 Nuclear Instruments & Methods in Physics Research Section B

巻 274, p. 36-41, 発行日 2012-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-583X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:54:03.604238
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3