ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Preliminary Calculation of RBE-weighted Dose Distribution for Cerebral Radionecrosis in Carbon-ion Treatment Planning

https://repo.qst.go.jp/records/46241
https://repo.qst.go.jp/records/46241
45d4f81c-79ec-423d-930c-37cb754a91ee
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-12-28
タイトル
タイトル Preliminary Calculation of RBE-weighted Dose Distribution for Cerebral Radionecrosis in Carbon-ion Treatment Planning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kase, Yuki

× Kase, Yuki

WEKO 460481

Kase, Yuki

Search repository
Himukai, Takeshi

× Himukai, Takeshi

WEKO 460482

Himukai, Takeshi

Search repository
Nagano, Ai

× Nagano, Ai

WEKO 460483

Nagano, Ai

Search repository
Minohara, Shinichi

× Minohara, Shinichi

WEKO 460484

Minohara, Shinichi

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 460485

Matsufuji, Naruhiro

Search repository
Mizoe, Junetsu

× Mizoe, Junetsu

WEKO 460486

Mizoe, Junetsu

Search repository
Fossati, Piero

× Fossati, Piero

WEKO 460487

Fossati, Piero

Search repository
Hasegawa, Azusa

× Hasegawa, Azusa

WEKO 460488

Hasegawa, Azusa

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 460489

Kanai, Tatsuaki

Search repository
日向 猛

× 日向 猛

WEKO 460490

en 日向 猛

Search repository
永野 あい

× 永野 あい

WEKO 460491

en 永野 あい

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 460492

en 蓑原 伸一

Search repository
松藤 成弘

× 松藤 成弘

WEKO 460493

en 松藤 成弘

Search repository
溝江 純悦

× 溝江 純悦

WEKO 460494

en 溝江 純悦

Search repository
Fossati Piero

× Fossati Piero

WEKO 460495

en Fossati Piero

Search repository
長谷川 安都佐

× 長谷川 安都佐

WEKO 460496

en 長谷川 安都佐

Search repository
金井 達明

× 金井 達明

WEKO 460497

en 金井 達明

Search repository
抄録
内容記述タイプ Abstract
内容記述 Cerebral radionecrosis is a significant side effect in radiotherapy for brain cancer. The purpose of this study is to calculate the relative biological effectiveness (RBE) of carbon-ion beams on brain cells and to show RBE-weighted dose distributions for cerebral radionecrosis speculation in a carbon-ion treatment planning system. The RBE value of the radionecrosis for the carbon-ion beam is calculated by the modified microdosimetric kinetic model on the assumption of a typical clinical alpha/beta ratio of 2 Gy for cerebral radionecrosis in X-rays. This calculation method for the RBE-weighted dose is built into the treatment planning system for the carbon-ion radiotherapy. The RBE-weighted dose distributions are calculated on computed tomography (CT) images of four patients who had been treated by carbon-ion radiotherapy for astrocytoma (WHO grade 2) and who suffered from necrosis around the target areas. The necrotic areas were detected by brain scans via magnetic resonance imaging (MRI) after the treatment irradiation. The detected necrotic areas are easily found near high RBE-weighted dose regions. The visual comparison between the RBE-weighted dose distribution and the necrosis region indicates that the RBE-weighted dose distribution will be helpful information for the prediction of radionecrosis areas after carbon-ion radiotherapy.
書誌情報 Journal of Radiation Research

巻 52, 号 6, p. 789-796, 発行日 2011
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:54:12.653494
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3