WEKO3
アイテム
High b-value diffusion-weighted fMRI in a rat forepaw electrostimulation model at 7T
https://repo.qst.go.jp/records/46235
https://repo.qst.go.jp/records/46235009c3118-41d9-4805-bd3d-af22a7a34177
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-12-26 | |||||
タイトル | ||||||
タイトル | High b-value diffusion-weighted fMRI in a rat forepaw electrostimulation model at 7T | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Joonas, Autio
× Joonas, Autio× Kershaw, Jeffrey× Shibata, Sayaka× Obata, Takayuki× Kanno, Iwao× Aoki, Ichio× ヨーナス オーティオ× Kershaw Jeffrey× 柴田 さやか× 小畠 隆行× 菅野 巖× 青木 伊知男 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Spin-echo diffusion-weighted functional MRI (DW-fMRI) was performed on a rat forepaw electrostimulation model at 7 T. This small animal model used electric (rather than visual) stimulation and allowed DW-fMRI experiments to be performed over a broader range of acquisition parameters than previous work on humans and cats. Resting state experiments with injections of ultra-small superparamagnetic iron oxide (USPIO) were also used to investigate the effects of gradient coupling on the signal change. The experiments were performed over five b-values (0, 200, 800, 1400 and 2000s/mm(2)) and three echo-times (30, 60 and 90 ms). Alterations to the stimulation-induced response with respect to TE and b-value were evaluated in two intervals: the positive stimulus-correlated response (5-20s after stimulus onset) and the post-stimulus undershoot (27-40s). There was no strong dependence of the signal change on b-value for any of the intervals or TEs. Similarly, changes to the apparent transverse relaxation rate showed no clear dependence on b-value. In contrast to previous DW-fMRI studies, the simplest explanation for the observed data is a single-compartment signal model with the functional signal changes probably corresponding to extravascular SE-BOLD. Experiments with USPIO suggested that at 7 T and within the range of parameters used, the influence of gradient coupling may be sufficient to explain minor DW-fMRI signal changes. | |||||
書誌情報 |
NeuroImage 巻 57, 号 1, p. 140-148, 発行日 2011-04 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1053-8119 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.neuroimage.2011.04.006 |