ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

High b-value diffusion-weighted fMRI in a rat forepaw electrostimulation model at 7T

https://repo.qst.go.jp/records/46235
https://repo.qst.go.jp/records/46235
009c3118-41d9-4805-bd3d-af22a7a34177
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-12-26
タイトル
タイトル High b-value diffusion-weighted fMRI in a rat forepaw electrostimulation model at 7T
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Joonas, Autio

× Joonas, Autio

WEKO 460414

Joonas, Autio

Search repository
Kershaw, Jeffrey

× Kershaw, Jeffrey

WEKO 460415

Kershaw, Jeffrey

Search repository
Shibata, Sayaka

× Shibata, Sayaka

WEKO 460416

Shibata, Sayaka

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 460417

Obata, Takayuki

Search repository
Kanno, Iwao

× Kanno, Iwao

WEKO 460418

Kanno, Iwao

Search repository
Aoki, Ichio

× Aoki, Ichio

WEKO 460419

Aoki, Ichio

Search repository
ヨーナス オーティオ

× ヨーナス オーティオ

WEKO 460420

en ヨーナス オーティオ

Search repository
Kershaw Jeffrey

× Kershaw Jeffrey

WEKO 460421

en Kershaw Jeffrey

Search repository
柴田 さやか

× 柴田 さやか

WEKO 460422

en 柴田 さやか

Search repository
小畠 隆行

× 小畠 隆行

WEKO 460423

en 小畠 隆行

Search repository
菅野 巖

× 菅野 巖

WEKO 460424

en 菅野 巖

Search repository
青木 伊知男

× 青木 伊知男

WEKO 460425

en 青木 伊知男

Search repository
抄録
内容記述タイプ Abstract
内容記述 Spin-echo diffusion-weighted functional MRI (DW-fMRI) was performed on a rat forepaw electrostimulation model at 7 T. This small animal model used electric (rather than visual) stimulation and allowed DW-fMRI experiments to be performed over a broader range of acquisition parameters than previous work on humans and cats. Resting state experiments with injections of ultra-small superparamagnetic iron oxide (USPIO) were also used to investigate the effects of gradient coupling on the signal change. The experiments were performed over five b-values (0, 200, 800, 1400 and 2000s/mm(2)) and three echo-times (30, 60 and 90 ms). Alterations to the stimulation-induced response with respect to TE and b-value were evaluated in two intervals: the positive stimulus-correlated response (5-20s after stimulus onset) and the post-stimulus undershoot (27-40s). There was no strong dependence of the signal change on b-value for any of the intervals or TEs. Similarly, changes to the apparent transverse relaxation rate showed no clear dependence on b-value. In contrast to previous DW-fMRI studies, the simplest explanation for the observed data is a single-compartment signal model with the functional signal changes probably corresponding to extravascular SE-BOLD. Experiments with USPIO suggested that at 7 T and within the range of parameters used, the influence of gradient coupling may be sufficient to explain minor DW-fMRI signal changes.
書誌情報 NeuroImage

巻 57, 号 1, p. 140-148, 発行日 2011-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 1053-8119
DOI
識別子タイプ DOI
関連識別子 10.1016/j.neuroimage.2011.04.006
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:54:16.334491
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3