ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Radiation measurements with heat-proof polyethylene terephthalate bottles

https://repo.qst.go.jp/records/46160
https://repo.qst.go.jp/records/46160
f2307b80-8773-487b-8267-c11665079af4
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-08-16
タイトル
タイトル Radiation measurements with heat-proof polyethylene terephthalate bottles
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakamura, Hidehito

× Nakamura, Hidehito

WEKO 459613

Nakamura, Hidehito

Search repository
Kitamura, Hisashi

× Kitamura, Hisashi

WEKO 459614

Kitamura, Hisashi

Search repository
Hazama, Ryuta

× Hazama, Ryuta

WEKO 459615

Hazama, Ryuta

Search repository
中村 秀仁

× 中村 秀仁

WEKO 459616

en 中村 秀仁

Search repository
北村 尚

× 北村 尚

WEKO 459617

en 北村 尚

Search repository
抄録
内容記述タイプ Abstract
内容記述 This study demonstrates that the energy resolution of a newly developed 100 per cent pure polyvinyltoluene (PVT) plate allows its use as a base material for a plastic scintillator. The energy resolution, which is a key element for high-performance radiation detectors, was ΔE/E=8.41±0.07% (full width at half maximum (FWHM)) for 976 keV K-line conversion electrons from a 207Bi source. On the basis of results from 207Bi and 137Cs sources, the observed energy resolution of the PVT plate, ΔE/E=8.2/E1/2% (FWHM), was slightly better than that of a typical plastic scintillator (BC-408), ΔE/E=8.7/E1/2% (FWHM), with E in units of MeV. These results prompted us to search for other new base materials for plastic scintillators. In this study, we examined polyethylene terephthalate (PET) bottles, a common source of domestic plastic waste. We demonstrated that a lump of heat-proof PET bottles is fluorescent; moreover, there is excellent compatibility of the fluorescence with the quantum efficiency of typical photomultiplier tubes. This inexpensive source of plastic appears suitable for radiation measurements and as a base material for plastic scintillators. Future studies on the radiation response of plastics should lead to the development of higher performance and more eco-friendly radiation detectors.
書誌情報 Proceedings of the Royal Society. Series A

巻 466, 号 2122, p. 2847-2856, 発行日 2010-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 1364-5021
DOI
識別子タイプ DOI
関連識別子 10.1098/rspa.2010.0118
関連サイト
識別子タイプ URI
関連識別子 http://rspa.royalsocietypublishing.org/content/466/2122/2847.abstract
関連名称 http://rspa.royalsocietypublishing.org/content/466/2122/2847.abstract
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:55:08.995636
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3