Estimation of background radiation doses for the Peninsular Malaysia's population by ESR dosimetry of tooth enamel

https://repo.qst.go.jp/records/46020
https://repo.qst.go.jp/records/46020
4506be10-99f7-40c8-a32d-f96f937ad19b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-03-25
タイトル
タイトル Estimation of background radiation doses for the Peninsular Malaysia's population by ESR dosimetry of tooth enamel
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Rodzi, B Ali Mohd

× Rodzi, B Ali Mohd

WEKO 458017

Rodzi, B Ali Mohd

Search repository
Zhumadilov, K.

× Zhumadilov, K.

WEKO 458018

Zhumadilov, K.

Search repository
Hoshi, Masaharu

× Hoshi, Masaharu

WEKO 458019

Hoshi, Masaharu

Search repository
Ivannikov, A.

× Ivannikov, A.

WEKO 458020

Ivannikov, A.

Search repository
Fukumura, Akifumi

× Fukumura, Akifumi

WEKO 458021

Fukumura, Akifumi

Search repository
et.al

× et.al

WEKO 458022

et.al

Search repository
Mohd Rodzi B Ali

× Mohd Rodzi B Ali

WEKO 458023

en Mohd Rodzi B Ali

Search repository
福村 明史

× 福村 明史

WEKO 458024

en 福村 明史

Search repository
抄録
内容記述タイプ Abstract
内容記述 Abstract Background radiation dose is used in dosimetry
for estimating occupational doses of radiation workers or
determining radiation dose of an individual following
accidental exposure. In the present study, the absorbed
dose and the background radiation level are determined
using the electron spin resonance (ESR) method on tooth
samples. The effect of using different tooth surfaces and
teeth exposed with single medical X-rays on the absorbed
dose are also evaluated. A total of 48 molars of position
6.8 were collected from 13 district hospitals in Peninsular
Malaysia. Thirty-six teeth had not been exposed to any
excessive radiation, and 12 teeth had been directly exposed
to a single X-ray dose during medical treatment prior to
extraction. There was no significant effect of tooth surfaces
and exposure with single X-rays on the measured absorbed
dose of an individual. The mean measured absorbed dose
of the population is 34 ± 6.2 mGy, with an average tooth
enamel age of 39 years. From the slope of a regression line,
the estimated annual background dose for Peninsular
Malaysia is 0.6 ± 0.3 mGy y -1. This value is slightly
lower than the yearly background dose for Malaysia, and
書誌情報 Radiation and Environmental Biophysics

巻 50, 号 3, p. 451-458, 発行日 2011-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0301-634X
DOI
識別子タイプ DOI
関連識別子 10.1007/s00411-011-0358-9
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:56:50.109897
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3