ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Functional oestrogen receptor a imaging in endometrial carcinoma using 16a-[18F]fluoro-17b-oestradiol PET

https://repo.qst.go.jp/records/46001
https://repo.qst.go.jp/records/46001
fe7d9bd7-9c45-4c31-8cdb-c59779611d72
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-02-21
タイトル
タイトル Functional oestrogen receptor a imaging in endometrial carcinoma using 16a-[18F]fluoro-17b-oestradiol PET
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Fujibayashi, Yasuhisa

× Fujibayashi, Yasuhisa

WEKO 457795

Fujibayashi, Yasuhisa

Search repository
et.al

× et.al

WEKO 457796

et.al

Search repository
藤林 康久

× 藤林 康久

WEKO 457797

en 藤林 康久

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose
To investigate the correlation between uptake of 16a-[18F]fluoro-17b-oestradiol (FES) and expression of oestrogen receptors as well as other related immunohistochemistry markers, positron emission tomography (PET) was performed in patients with endometrial carcinoma before surgery.
Methods
Nineteen patients with endometrioid adenocarcinoma underwent preoperative PET studies with FES and 2-[18F]fluoro-2-deoxy-D-glucose (FDG). Standardized uptake values (SUVs) for each tracer and the regional FDG to FES SUV ratio were calculated using images after coregistration. PET values were compared with postoperative stage, differentiation grade and immunohistochemical scores including oestrogen receptor subtypes (ERa, ERb), progesterone receptor B (PR-B), Ki-67 and glucose transporter 1 (GLUT1).
Results
FES uptake showed a significantly positive correlation with expression of ERa. The FDG to FES ratio showed a significantly negative correlation with expression of ERa and PR-B. The FES uptake and FDG to FES ratio did not correlate with expression of ERb, Ki-67 or GLUT1. FDG uptake was not correlated with any of the immunohistochemical scores. The PR-B score was strongly correlated with the ERa score. Well-differentiated carcinoma (grade 1) showed a significantly higher FES uptake and significantly lower FDG to FES ratio than moderately or poorly differentiated carcinoma (grade 2–3). None of the PET parameters were significantly different between advanced-stage carcinoma (≥ stage IB) and early-stage carcinoma (IA) based on the Féderation International de Gynécologie et d'Obstétrique (FIGO) staging classification. Differentiation grade was the most closely correlated parameter to FES uptake and FDG to FES ratio by multivariate analyses.
Conclusion
FES PET combined with FDG would be useful for non-invasive evaluation of ERa distribution, as well as ERa function, which reflects differentiation grade in endometrial carcinoma.
書誌情報 European Journal of Nuclear Medicine and Molecular Imaging

巻 38, 号 1, p. 37-45, 発行日 2010-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 1619-7070
DOI
識別子タイプ DOI
関連識別子 10.1007/s00259-010-1589-8
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:57:03.785499
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3