Dose-response effect of charged carbon beam on normal rat retina assessed by electroretinography

https://repo.qst.go.jp/records/45982
https://repo.qst.go.jp/records/45982
f5e963bb-8190-4da6-adfc-70ea3e2e29bd
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-01-07
タイトル
タイトル Dose-response effect of charged carbon beam on normal rat retina assessed by electroretinography
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mizota, Jun

× Mizota, Jun

WEKO 457527

Mizota, Jun

Search repository
Tanaka, Minoru

× Tanaka, Minoru

WEKO 457528

Tanaka, Minoru

Search repository
Kubota, Mariko

× Kubota, Mariko

WEKO 457529

Kubota, Mariko

Search repository
Negishi, Hisanari

× Negishi, Hisanari

WEKO 457530

Negishi, Hisanari

Search repository
Watanabe, Emiko

× Watanabe, Emiko

WEKO 457531

Watanabe, Emiko

Search repository
Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 457532

Tsuji, Hiroshi

Search repository
Miyahara, Nobuyuki

× Miyahara, Nobuyuki

WEKO 457533

Miyahara, Nobuyuki

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 457534

Furusawa, Yoshiya

Search repository
辻 比呂志

× 辻 比呂志

WEKO 457535

en 辻 比呂志

Search repository
宮原 信幸

× 宮原 信幸

WEKO 457536

en 宮原 信幸

Search repository
古澤 佳也

× 古澤 佳也

WEKO 457537

en 古澤 佳也

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To compare the effects of carbon beam irradiation with those of proton beam irradiation on the physiology of the retina of rats. Methods and Materials: Eight-week-old Wister rats were used. The right eyes were irradiated with carbon beam (1, 2, 4, 8, and 16 Gy) or proton beam (4, 8, 16, and 24 Gy) with the rats under general anesthesia. Electroretino- grams were recorded 1, 3, 6, and 12 months after the irradiation, and the amplitudes of the a and b waves were compared with those of control rats.
Results: The amplitude of b waves was reduced more than that of a waves at lower irradiation doses with both types of irradiation. With carbon ion irradiation, the amplitudes of the b wave were significantly reduced after radiation doses of 8 and 16 Gy at 6 months and by radiation doses of 4, 8, and 16 Gy at 12 months. With proton beam irradiation, the b-wave amplitudes were significantly reduced after 16 and 24 Gy at 6 months and with doses of 8 Gy or greater at 12 months. For the maximum b-wave amplitude, a significant difference was observed in rats irradiated with carbon beams of 4 Gy or more and with proton beams of 8 Gy or more at 12 months after irradiation.
Conclusions: These results indicate that carbon beam irradiation is about two times more damaging than proton beam irradiation on the rat retina at the same dose.
書誌情報 International Journal of Radiation Oncology Biology Physics

巻 78, 号 5, p. 1532-1540, 発行日 2010-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0360-3016
DOI
識別子タイプ DOI
関連識別子 10.1016/j.ijrobp.2010.07.003
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:57:17.387075
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3