ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Study of the characteristics of a piezoelectric lead zirconate titanate radiation detector using a pulsed xenon source

https://repo.qst.go.jp/records/45944
https://repo.qst.go.jp/records/45944
29a79fa0-cf5a-4a62-900e-7e930171939d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-11-19
タイトル
タイトル Study of the characteristics of a piezoelectric lead zirconate titanate radiation detector using a pulsed xenon source
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Miyachi, Takashi

× Miyachi, Takashi

WEKO 457073

Miyachi, Takashi

Search repository
Fujii, Masayuki

× Fujii, Masayuki

WEKO 457074

Fujii, Masayuki

Search repository
Hasebe, Nobuyuki

× Hasebe, Nobuyuki

WEKO 457075

Hasebe, Nobuyuki

Search repository
Okudaira, Osamu

× Okudaira, Osamu

WEKO 457076

Okudaira, Osamu

Search repository
Takechi, Seiji

× Takechi, Seiji

WEKO 457077

Takechi, Seiji

Search repository
Kurozumi, Atsuma

× Kurozumi, Atsuma

WEKO 457078

Kurozumi, Atsuma

Search repository
Uno, Takefumi

× Uno, Takefumi

WEKO 457079

Uno, Takefumi

Search repository
Shibata, Hiromi

× Shibata, Hiromi

WEKO 457080

Shibata, Hiromi

Search repository
Kobayashi, Masanori

× Kobayashi, Masanori

WEKO 457081

Kobayashi, Masanori

Search repository
Murakami, Takeshi

× Murakami, Takeshi

WEKO 457082

Murakami, Takeshi

Search repository
Uchihori, Yukio

× Uchihori, Yukio

WEKO 457083

Uchihori, Yukio

Search repository
Okada, Nagaya

× Okada, Nagaya

WEKO 457084

Okada, Nagaya

Search repository
宇野 豪文

× 宇野 豪文

WEKO 457085

en 宇野 豪文

Search repository
村上 健

× 村上 健

WEKO 457086

en 村上 健

Search repository
内堀 幸夫

× 内堀 幸夫

WEKO 457087

en 内堀 幸夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 The detector characteristics of piezoelectric lead zirconate titanate (PZT) were studied by directly irradiating a multilayered PZT detector with 400 MeV/n xenon ions. An extracted beam was processed with a rotating slit. Thus, passed through ∼ 103 xenon ions were available for 50 to 250μs. The effect of polarization on the output signal was discussed, and the optimal electrode configuration was determined. The output signal appeared as an isolated pulse whose amplitude was qualitatively understood by the Bethe–Bloch formula. However, the calculated and the observed values differed depending on the rotation speed of the slit. A process that can explain the differences is presented here. The output signal appearing beyond the range of 400 MeV/n xenon ion beam was discussed. The sensitivity was compared with that obtained with hypervelocity collision of dust.
書誌情報 Journal of Applied Physics

巻 107, 号 10, p. 104902-1-104902-6, 発行日 2010-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0021-8979
DOI
識別子タイプ DOI
関連識別子 10.1063/1.3373383
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:57:44.385133
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3