ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Natural radioactivities in iron and nickel ores imported into Japan and the dose assessment for workers handling them

https://repo.qst.go.jp/records/45892
https://repo.qst.go.jp/records/45892
58faaa33-6240-4b5f-b21b-961772d3190a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-09-09
タイトル
タイトル Natural radioactivities in iron and nickel ores imported into Japan and the dose assessment for workers handling them
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 456512

Iwaoka, Kazuki

Search repository
Tagami, Keiko

× Tagami, Keiko

WEKO 456513

Tagami, Keiko

Search repository
Yonehara, Hidenori

× Yonehara, Hidenori

WEKO 456514

Yonehara, Hidenori

Search repository
岩岡 和輝

× 岩岡 和輝

WEKO 456515

en 岩岡 和輝

Search repository
田上 恵子

× 田上 恵子

WEKO 456516

en 田上 恵子

Search repository
米原 英典

× 米原 英典

WEKO 456517

en 米原 英典

Search repository
抄録
内容記述タイプ Abstract
内容記述 In Japan, Fe and Ni ores are imported from foreign countries to be used as industrial raw materials for manufacturing industrial products like stainless steel. A part of these ores might contain high radioactivity, and then workers handling these ores would be exposed to radiations without being aware of it. Activity concentrations in these ores should be measured to evaluate the radiation exposure of workers.
In this study, Fe and Ni ores used as industrial raw materials were collected from iron and steel companies, and the activity concentrations of 238U series, 232Th series and 40K in these ores were determined using ICP-MS and gamma ray spectrometry. The activity concentrations of 238U series, 232Th series and 40K in these ores samples were lower than the IAEA values. The doses to workers handling these ores were estimated using methods for dose assessment given in a report by the European Commission. In each scenario, a maximum value of annual effective doses for them was estimated to be about 6.8  10-6 Sv, which was lower than intervention exemption levels (annual dose: 1.0  10-3 Sv) given in ICRP Publication 82.
書誌情報 Journal of Radiological Protection

巻 30, 号 3, p. 613-620, 発行日 2010-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0952-4746
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:58:20.736253
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3